UnoViS: the MedIT public unobtrusive vital signs database

AbstractWhile PhysioNet is a large database for standard clinical vital signs measurements, such a database does not exist for unobtrusively measured signals. This inhibits progress in the vital area of signal processing for unobtrusive medical monitoring as not everybody owns the specific measurement systems to acquire signals. Furthermore, if no common database exists, a comparison between different signal processing approaches is not possible. This gap will be closed by our UnoViS database. It contains different recordings in various scenarios ranging from a clinical study to measurements obtained while driving a car. Currently, 145 records with a total of 16.2 h of measurement data is available, which are provided as MATLAB files or in the PhysioNet WFDB file format. In its initial state, only (multichannel) capacitive ECG and unobtrusive PPG signals are, together with a reference ECG, included. All ECG signals contain annotations by a peak detector and by a medical expert. A dataset from a clinical study contains further clinical annotations. Additionally, supplementary functions are provided, which simplify the usage of the database and thus the development and evaluation of new algorithms. The development of urgently needed methods for very robust parameter extraction or robust signal fusion in view of frequent severe motion artifacts in unobtrusive monitoring is now possible with the database.

[1]  Tomás Ward,et al.  Artifact Removal in Physiological Signals—Practices and Possibilities , 2012, IEEE Transactions on Information Technology in Biomedicine.

[2]  Donald Y.C. Lie,et al.  A 2.4GHz non-contact biosensor system for continuous vital-signs monitoring , 2009, 2009 IEEE 10th Annual Wireless and Microwave Technology Conference.

[3]  Rik Vullings,et al.  Motion Artifacts in Capacitive ECG Measurements: Reducing the Combined Effect of DC Voltages and Capacitance Changes Using an Injection Signal , 2015, IEEE Transactions on Biomedical Engineering.

[4]  Chuan Yi Tang,et al.  A 2.|E|-Bit Distributed Algorithm for the Directed Euler Trail Problem , 1993, Inf. Process. Lett..

[5]  Steffen Leonhardt,et al.  Automatic electrode selection in unobtrusive capacitive ECG measurements , 2012, 2012 25th IEEE International Symposium on Computer-Based Medical Systems (CBMS).

[6]  P. Schauerte,et al.  The Reliability and Accuracy of a Noncontact Electrocardiograph System for Screening Purposes , 2012, Anesthesia and analgesia.

[7]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[8]  Automobil und Flugtechnische Gesellschaft ATZ : Automobiltechnische Zeitschrift , 1934 .

[9]  Steffen Leonhardt,et al.  Modeling of motion artifacts in contactless heart rate measurements , 2013, Computing in Cardiology 2013.

[10]  Stephan Heuer,et al.  Motion artefact correction for capacitive ECG measurement , 2009, 2009 IEEE Biomedical Circuits and Systems Conference.

[11]  T. D. Clark,et al.  Ultrahigh impedance capacitively coupled heart imaging array , 1994 .

[12]  Akinori Ueno,et al.  An Application of Capacitive Electrode for Detecting Electrocardiogram of Neonates and Infants , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  S Leonhardt,et al.  Robust inter-beat interval estimation in cardiac vibration signals , 2013, Physiological measurement.

[14]  L. Scalise Non Contact Heart Monitoring , 2012 .

[15]  Steffen Leonhardt,et al.  ECG on the Road: Robust and Unobtrusive Estimation of Heart Rate , 2011, IEEE Transactions on Biomedical Engineering.

[16]  Janko Drnovsek,et al.  Novel Methods for Noncontact Heart Rate Measurement: A Feasibility Study , 2014, IEEE Transactions on Instrumentation and Measurement.

[17]  Steffen Leonhardt,et al.  Capacitive electrocardiogram measurement system in the driver seat , 2011 .

[18]  Carmen C. Y. Poon,et al.  Unobtrusive Sensing and Wearable Devices for Health Informatics , 2014, IEEE Transactions on Biomedical Engineering.

[19]  Ko Keun Kim,et al.  A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals , 2012, IEEE Transactions on Information Technology in Biomedicine.

[20]  James T. Patrie,et al.  Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System , 2009, IEEE Transactions on Information Technology in Biomedicine.

[21]  J. M. Kortelainen,et al.  Multichannel bed pressure sensor for sleep monitoring , 2012, 2012 Computing in Cardiology.

[22]  Steffen Leonhardt,et al.  On the way to a cable free operating theater: An operating table with integrated multimodal monitoring , 2011, 2011 Computing in Cardiology.

[23]  Steffen Leonhardt,et al.  Robust Sensor Fusion of Unobtrusively Measured Heart Rate , 2014, IEEE Journal of Biomedical and Health Informatics.

[24]  J.M. Kortelainen,et al.  FFT averaging of multichannel BCG signals from bed mattress sensor to improve estimation of heart beat interval , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Gert Cauwenberghs,et al.  Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing , 2011, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[26]  Marcelo Haberman,et al.  A capacitive electrode with fast recovery feature , 2012, Physiological measurement.

[27]  P. Hamilton,et al.  Open source ECG analysis , 2002, Computers in Cardiology.

[28]  Steffen Leonhardt,et al.  Kapazitives Elektrokardiogramm-Messsystem im Autositz , 2011 .

[29]  Mark F. Bocko,et al.  Non-Contact ECG Sensing Employing Gradiometer Electrodes , 2013, IEEE Transactions on Biomedical Engineering.