Effect of reduction in seal clearances on leakages in a rotary heat exchanger

Abstract An experimental investigation was undertaken of the effect of seal clearances on leakages in a rotary regenerator. The measurements were carried out before and after a reduction in radial seal clearances. On the basis of these measurements the direct effect of reduction in seal clearances on leakages was shown.