Application of EMD and STFT Methods in Analysis of Energization of an Unloaded Overhead Line Under Different Operating Conditions

Maintaining of voltage conditions recommended by EN 50160 Standard is ultimate aim related to power quality. This issue gets an additional importance in era of modern power systems and smart grid environments. Occurrence of voltage whose magnitude exceeds the highest voltage level recommended for proper electrical equipment operation is known as overvoltage. Switching operation such as line energization can cause this type of disturbance. The paper deals with switching overvoltages occurred during energization of an unloaded overhead transmission line under different operating conditions. Namely, this process can be performed under normal or fault conditions. The latter means that some kind of fault has occured along the line and exists at the moment of energization. Switching overvoltages have to be analyzed not only from the aspect of magnitude, but also from the aspect of the existing harmonics in the harmonic spectrum. Accordingly, the Empirical Mode Decomposition and Short time Fourier Transform were used. The obtained results were compared to the calculated ones. In this way, one may get characteristic harmonics values which occur during the energization process, what would make a worthwhile contribution related to recognition of operating conditions during energization. Also, a conclusion about applied methods efficiency is drawn.

[1]  N. R. Watson,et al.  Power Quality State Estimator for Smart Distribution Grids , 2013, IEEE Transactions on Power Systems.

[2]  Ivo Uglešić,et al.  Application of Line Surge Arresters for Voltage Uprating and Compacting of Overhead Transmission Lines , 2016 .

[3]  Mukesh Nagpal,et al.  Damaging Open-Phase Overvoltage Disturbance on a Shunt-Compensated 500-kV Line Initiated by Unintended Trip , 2015, IEEE Transactions on Power Delivery.

[4]  S. Seyedtabaii,et al.  Improvement in the performance of neural network-based power transmission line fault classifiers , 2012 .

[5]  D. Guillen,et al.  Detection and classification of faults in transmission lines using the maximum wavelet singular value and Euclidean norm , 2015 .

[6]  Surajit Chattopadhyay,et al.  Electric Power Quality , 2011 .

[7]  Heresh Seyedi,et al.  New controlled switching approach for limitation of transmission line switching overvoltages , 2013 .

[8]  B. K. Panigrahi,et al.  Optimal feature selection for classification of power quality disturbances using wavelet packet-based fuzzy k-nearest neighbour algorithm , 2009 .

[9]  Iulian Birou,et al.  Correct Application of the Discrete Fourier Transform in Harmonics , 2008 .

[10]  Julio Barros,et al.  Applications of wavelets in electric power quality: Voltage events , 2012 .

[11]  Reza Iravani,et al.  Modeling nonuniform transmission lines for time domain simulation of electromagnetic transients , 2002 .

[12]  Samir Avdakovic,et al.  Wavelet transform applications in power system dynamics , 2012 .

[13]  V. A. Katic,et al.  The Hybrid Method for On-line Harmonic Analysis , 2011 .

[14]  Lj M Popović Algorithm for single phase-to-ground fault digital distance relay , 2012 .