Effect of the homogeneity of the column set on the performance of a simulated moving bed unit. II. Experimental study.

Previous studies of the simulated moving bed (SMB) process assume identical characteristics of all the columns incorporated in a given unit. Due to the practical impossibility to manufacture identical columns, numerical applications of the theory to modeling and optimization use for each of the needed column parameter the average value for the entire column set. In this study, the effects of these simplifications on the actual productivity of the SMB process are evaluated by making exact calculations, i.e., by taking the differences in the porosity values into account. We apply a revised set of separation conditions previously introduced and derived from the equilibrium theory. Earlier theoretical results are compared to experimental results obtained in the study of the enantiomeric separation of Tröger's base on Chiralpak AD. Due to the nonLangmuirian character of the adsorption isotherms of these two compounds on the packing material used, the separation area cannot be determined analytically. As an alternative, a reliable numerical algorithm was used to scan a wider region and to define the separation area. The form of this area depends on the applied porosity values. A UV detector and a laser polarimeter located at one node of the SMB monitor on-line the internal concentration profiles. Excellent agreement between the calculated and the experimentally determined concentration profiles was obtained under nonlinear conditions. The influence of column-to-column variations on the performance of the SMB process was found to be more significant under nonlinear than under linear conditions.

[1]  M. Morbidelli,et al.  Design and optimisation of a simulated moving bed unit: role of deviations from equilibrium theory. , 2000, Journal of chromatography. A.

[2]  Zidu Ma,et al.  Optimization of throughput and desorbent consumption in simulated moving-bed chromatography for paclitaxel purification. , 1999, Journal of chromatography. A.

[3]  D. Ruthven,et al.  Counter-current and simulated counter-current adsorption separation processes , 1989 .

[4]  Sebastian Engell,et al.  Model-based optimization and control of chromatographic processes , 2000 .

[5]  Ernst Dieter Gilles,et al.  Automatic control of the simulated moving bed process for C8 aromatics separation using asymptotically exact input/output-linearization , 1999 .

[6]  D. Goodall Chiral analysis based on polarimetric detection , 1993 .

[7]  Massimo Morbidelli,et al.  Optimal design of multicomponent countercurrent adsorption separation processes involving nonlinear equilibria , 1989 .

[8]  Massimo Morbidelli,et al.  Robust design of binary countercurrent adsorption separation processes , 1993 .

[9]  G. Guiochon,et al.  On the reproducibility of column performance in liquid chromatography and the role of the packing density , 1997 .

[10]  H Schmidt-Traub,et al.  Effect of the homogeneity of the column set on the performance of a simulated moving bed unit. I. Theory. , 2001, Journal of chromatography. A.

[11]  S. Sekulic,et al.  APPLICATIONS OF A SENSITIVE LASER POLARIMETRIC HPLC DETECTOR: CONFIRMATION OF ENANTIOMERIC EXCESS FOR DANOFLOXACIN AND ANALYSIS OF A NOVEL MACROLIDE , 2000 .

[12]  Gerard Hotier,et al.  Remote Raman spectroscopy for process control , 1995 .

[13]  Andreas Seidel-Morgenstern,et al.  Design of the simulated moving bed process based on adsorption isotherm measurements using a perturbation method , 1998 .

[14]  G. Guiochon,et al.  Study of the operating conditions of axial compression columns for preparative chromatography , 1995 .

[15]  Massimo Morbidelli,et al.  Simulated moving‐bed units with extra‐column dead volume , 1999 .

[16]  G. Grévillot,et al.  Equilibria and activity coefficients for non-ideal adsorbed mixtures from perturbation chromatography , 1998 .

[17]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[18]  Georges Guiochon,et al.  Adsorption isotherm and overloaded elution profiles of phenyldodecane on porous carbon in liquid chromatography , 1991 .

[19]  P. Hubert,et al.  Comparative evaluation of four detectors in the high-performance liquid chromatographic analysis of chiral nonaromatic alcohols. , 2000, Journal of chromatographic science.

[20]  G. Guiochon,et al.  Theoretical analysis of the behavior of an heterogeneously packed chromatographic column , 1998 .

[21]  Enantioseparation of 1-phenyl-1-propanol by simulated moving bed under linear and nonlinear conditions. , 2000, Journal of chromatography. A.

[22]  E. Glueckauf,et al.  239. Theory of chromatography. Part II. Chromatograms of a single solute , 1947 .

[23]  G. Guiochon,et al.  Thermodynamics of the adsorption of Tröger's base enantiomers from ethanol on cellulose triacetate , 1993 .

[24]  Massimo Morbidelli,et al.  Optimal operation of simulated moving bed units for nonlinear chromatographic separations , 1997 .

[25]  Massimo Morbidelli,et al.  Experimental analysis of a chiral separation through simulated moving bed chromatography , 1999 .

[26]  M. Morbidelli,et al.  On-line monitoring of enantiomer concentration in chiral simulated moving bed chromatography. , 2000, Journal of chromatography. A.

[27]  G. Guiochon,et al.  Effect of column efficiency on the internal concentration profiles and the performance of a simulated moving-bed unit in the case of a linear isotherm , 1997 .

[28]  G. Guiochon,et al.  Experimental study of the influence of the flow rates in SMB chromatography , 1997 .

[29]  F. G. Sánchez,et al.  Resolution of deltamethrin, permethrin, and cypermethrin enantiomers by high-performance liquid chromatography with diode-laser polarimetric detection , 1998 .

[30]  A. Rodrigues,et al.  Enantiomers separation by simulated moving bed chromatography. Non-instantaneous equilibrium at the solid-fluid interface. , 1999, Journal of Chromatography A.