Investigation and Evaluation of Winter Indoor Air Quality of Primary Schools in Severe Cold Weather Areas of China

The indoor air quality (IAQ) in classrooms has attracted more and more attention. Unfortunately, there is limited information relating to IAQ in the primary schools in severe cold weather areas of China. In this study, a field investigation on the IAQ of a primary school of Shenyang in northeast China was carried out by physical measurements and questionnaire surveys. The carbon dioxide (CO2) concentration in selected classrooms was continuously measured for a week, and the corresponding ventilation rate was calculated. Meanwhile, the perceptions of the IAQ, the purpose and the comfort degree of window opening have also been recorded from 106 pupils, aged 9–12. The results indicate the ventilation rate is considerably inadequate in about 99% of the class time due to the low frequency of window opening. The average daily CO2 concentration in these classrooms is 1510–3863 ppm, which is far higher than the recommended value of 1000 ppm. Most pupils understand that the purpose of opening windows in winter is to improve air quality. However, there are big differences between the measurement results and subjective judgments of indoor air quality. Contrary to the high measured CO2 concentration, around 70% pupils consider the air fresh, and only 3.7% pupils are dissatisfied and even very dissatisfied with IAQ in their classroom. It is necessary to change the existing manual window opening mode, because the pupils’ subjective judgment affects the window opening behavior.

[1]  Angelamaria Massimo,et al.  The effect of natural ventilation strategy on indoor air quality in schools. , 2017, The Science of the total environment.

[2]  H Fromme,et al.  Effect of classroom air quality on students' concentration: results of a cluster-randomized cross-over experimental study. , 2012, Indoor air.

[3]  W. Fisk The ventilation problem in schools: literature review , 2017, Indoor air.

[4]  P. Wargocki,et al.  The Effects of Moderately Raised Classroom Temperatures and Classroom Ventilation Rate on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[5]  P. Wargocki,et al.  Effects of HVAC on student performance , 2006 .

[6]  Zhen Peng,et al.  Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China , 2017 .

[7]  C. Kielb,et al.  Classroom conditions and CO2 concentrations and teacher health symptom reporting in 10 New York State Schools. , 2015, Indoor air.

[8]  Manuel Gameiro da Silva,et al.  Assessment of indoor air quality and thermal comfort in Portuguese secondary classrooms: Methodology and results , 2014 .

[9]  Steve Turner,et al.  Classroom carbon dioxide concentration, school attendance, and educational attainment. , 2014, The Journal of school health.

[10]  U. Haverinen-Shaughnessy,et al.  Association between substandard classroom ventilation rates and students' academic achievement. , 2011, Indoor air.

[11]  Mattheos Santamouris,et al.  An integrated evaluation study of the ventilation rate, the exposure and the indoor air quality in naturally ventilated classrooms in the Mediterranean region during spring. , 2015, The Science of the total environment.

[12]  Mahroo Eftekhari,et al.  Control of CO2 in a naturally ventilated classroom , 2008 .

[13]  Francesca Stazi,et al.  Indoor air quality and thermal comfort optimization in classrooms developing an automatic system for windows opening and closing , 2017 .

[14]  Monica Paciuk,et al.  Improving energy performance of school buildings while ensuring indoor air quality ventilation , 2007 .

[15]  Michele De Carli,et al.  Indoor environmental quality and pupil perception in Italian primary schools , 2012 .

[16]  W. Fisk,et al.  Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance , 2012, Environmental health perspectives.

[17]  D Faulkner,et al.  Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. , 2004, Indoor air.

[18]  Moshood Olawale Fadeyi,et al.  Evaluation of indoor environmental quality conditions in elementary schools' classrooms in the United Arab Emirates , 2014 .

[19]  Ray Kirby,et al.  Indoor Air Quality in U.K. School Classrooms Ventilated by Natural Ventilation Windcatchers , 2012 .

[20]  Massimiliano Scarpa,et al.  Natural Ventilation Level Assessment in a School Building by CO2 Concentration Measures , 2016 .

[21]  S. Batterman,et al.  Indoor air quality in Michigan schools. , 2007, Indoor air.

[22]  Despoina Teli,et al.  Thermal comfort in naturally ventilated primary school classrooms , 2013 .

[23]  Zs. Bakó-Birób,et al.  Ventilation rates in schools and pupils performance , 2011 .

[24]  Derek Clements-Croome,et al.  Ventilation rates in schools and pupils' performance , 2012 .

[25]  Moshood Olawale Fadeyi,et al.  A preliminary study of indoor air quality conditions in Dubai public elementary schools , 2012 .

[26]  Pawel Wargocki,et al.  Research Report on Effects of HVAC on Student Performance , 2006 .

[27]  Cristina Cornaro,et al.  Monitoring Indoor Carbon Dioxide Concentration and Effectiveness of Natural Trickle Ventilation in a Middle School in Rome , 2013 .

[28]  K. Pavlou,et al.  Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation , 2008 .

[29]  Pawel Wargocki,et al.  The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[30]  E. Faustman,et al.  Mechanisms underlying Children's susceptibility to environmental toxicants. , 2000, Environmental health perspectives.

[31]  Nikola Mirkov,et al.  Indoor CO2 measurements in Serbian schools and ventilation rate calculation , 2014 .

[32]  Dengjia Wang,et al.  Student responses to classroom thermal environments in rural primary and secondary schools in winter , 2017 .

[33]  M. Alvim-Ferraz,et al.  Children's exposure to indoor air in urban nurseries-part I: CO₂ and comfort assessment. , 2015, Environmental research.

[34]  Jørn Toftum,et al.  Association between classroom ventilation mode and learning outcome in Danish schools , 2015 .

[35]  Ian Ridley,et al.  Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England , 2009 .

[36]  David A. Coley,et al.  The Effect of Low Ventilation Rates on the Cognitive Function of a Primary School Class , 2007 .

[37]  A. Persily,et al.  Carbon dioxide generation rates for building occupants , 2017, Indoor air.

[38]  Costanzo Di Perna,et al.  Ventilation Strategies in School Buildings for Optimization of Air Quality, Energy Consumption and Environmental Comfort in Mediterranean Climates , 2011 .

[39]  William A Suk,et al.  Environmental hazards to children's health in the modern world. , 2003, Mutation research.

[40]  S M Almeida,et al.  Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France. , 2016, Indoor air.

[41]  David Coley,et al.  Carbon Dioxide Levels and Ventilation Rates in Schools , 2002 .

[42]  P Wargocki,et al.  Use of visual CO2 feedback as a retrofit solution for improving classroom air quality. , 2015, Indoor air.