Fano-Noise-Limited CCDs

Recent developments of scientific CCDs have produced sensors that achieve ultra low read noise performance (less than 2 electrons rms) and near perfect charge transfer efficiency (0.9999996) without the addition of a fat-zero. This progress has now made it possible to achieve Fano-noise-limited performance in the soft x-ray where the detector's energy resolution is primarily limited by the statistical variation in the charge generated by the interacting x-ray photon. In this paper, Fano-noise-limited test data is presented for two different CCD types and a CCD derived estimate of the Fano factor is determined. By evaluating ultra low-modulation images (less than 1 electron peak-to-peak) it is shown that the CCD's global CTE is now superior to its read noise floor. To capitalize on this capability CCD manufacturers are now focusing their attention on reducing the noise floor below the 1 electron level thereby matching the sensor's CTE performance. This improvement, if accomplished, will push Fano-noise-limited performance for the CCD into the extreme ultra-violet.

[1]  J. P. Dupin,et al.  Thomson-CSF frame-transfer charge-coupled-device imagers: design and evaluation at very low flux level , 1987 .

[2]  L. Esser,et al.  The peristaltic charge-coupled device for high-speed charge transfer , 1974 .

[3]  Barry E. Burke,et al.  420 X420 Charge-Coupled-Device Imager And Four-Chip Hybrid Focal Plane , 1987 .

[4]  河村 信雄 Charge Coupled Device(パーラー) , 1971 .

[5]  J. Janesick,et al.  Charge-Coupled-Device Charge-Collection Efficiency And The Photon-Transfer Technique , 1987 .

[6]  James R. Janesick,et al.  Current status of the 800 x 800 charge-coupled-device image sensor , 1987 .

[7]  Taher Daud,et al.  Charge-Coupled Device Advances For X-Ray Scientific Applications In 1986 , 1987 .

[8]  David W. Latham,et al.  Instrumentation for ground-based optical astronomy. Present and future. The Ninth Santa Cruz Summer Workshop in Astronomy and Astrophysics,held at the Lick Observatory, Santa Cruz, CA, USA, 13 - 24 July 1987. , 1988 .

[9]  James R. Janesick,et al.  Evaluation of a virtual phase charged‐coupled device as an imaging x‐ray spectrometer , 1983 .

[10]  Denis L. Heidtmann,et al.  Large format, high resolution image sensors , 1987 .

[11]  U. Fano Ionization Yield of Radiations. II. The Fluctuations of the Number of Ions , 1947 .

[12]  James R. Janesick,et al.  The CCD Flash Gate , 1986, Astronomical Telescopes and Instrumentation.

[13]  D. W. Aitken,et al.  Fano Factor Fact and Fallacy , 1970 .