High-speed soft x-ray techniques

The construction and the characteristics of recent high- speed soft x-ray generators designed by the authors are described. The flash x-ray generators having cold-cathode radiation tubes are three types as follows: (1) soft generator utilizing an ignitron, (2) plasma generator for producing high-intensity characteristic x rays, and (3) water-window generator having a high-durability fermite capillary. In general, when we employed the flash x-ray generators with diodes, the pulse widths had values of less than 200 ns. Next, the x-ray duration was almost equivalent to the durations of the tube voltage and current during their damped oscillations when the water-window generator was employed. The maximum tube voltage was increased up to 100 kV, and the tube currents achieved with high-intensity generators were more than 10 kA. In order to obtain kilohertz-range repetition rates, we have developed two types of stroboscopic x-ray generators having hot-cathode tubes as follows: (4) low-photon-energy generator utilizing and triode and (5) high-photon-energy generator with a diode. As the duration was controlled in a microsecond range by using the low-photon-energy generator, sufficient x-ray intensifier for the normal radiography were obtained. The maximum photon energy could be increased up to about 200 keV by the high-photon-energy generator having a double transformer. Using these generation, we performed high-speed soft radiography.

[1]  Eiichi Sato,et al.  Repetitive flash x‐ray generator utilizing a simple diode with a new type of energy‐selective function , 1990 .

[2]  T Kanayama,et al.  Three-dimensional readout of flash x-ray images of living sperm in water by atomic-force microscopy. , 1991, Science.

[3]  Eiichi Sato,et al.  Kilohertz-range harder pulsed x-ray generator utilizing a hot-cathode diode , 1995, Optics & Photonics.

[4]  Eiichi Sato,et al.  Fundamental study on a long-duration flash x-ray generator with a surface-discharge triode , 1994 .

[5]  Eiichi Sato,et al.  Repetitive compact flash x-ray generators for soft radiography , 1993, Other Conferences.

[6]  Eiichi Sato,et al.  Characteristics of a high-intensity plasma flash x-ray generator having a double-target radiation tube , 1995, International Congress on High-Speed Imaging and Photonics.

[7]  Eiichi Sato,et al.  High-intensity vacuum-ultraviolet generator utilizing a surface-discharge diode , 1995, International Congress on High-Speed Imaging and Photonics.

[8]  Eiichi Sato,et al.  Surface-discharge characteristics in a ferrite-cathode diode , 1995, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  A Mattsson Some Characteristics of a 600 kV Flash X-ray Tube , 1972 .

[10]  Eiichi Sato,et al.  High-intensity flash x-ray apparatus for biomedical radiography , 1986 .

[11]  M. Sonoda,et al.  Computed radiography utilizing scanning laser stimulated luminescence. , 1983, Radiology.

[12]  Eiichi Sato,et al.  Flash vacuum-ultraviolet source utilizing a surface-discharge substrate , 1993, Other Conferences.

[13]  Eiichi Sato,et al.  Kilohertz to megahertz soft flash x-ray generators utilizing hot-cathode radiation tubes , 1993, Other Conferences.

[14]  Eiichi Sato,et al.  Plasma-flash radiography utilizing a molybdenum target in dentistry , 1995, Optics & Photonics.

[15]  Eiichi Sato,et al.  Generation of flash vacuum-ultraviolet rays from a surface-discharge glass substrate , 1993, Optics & Photonics.

[16]  Eiichi Sato,et al.  Repetitive flash x‐ray generator having a high‐durability diode driven by a two‐cable‐type line pulser , 1994 .

[17]  O.D. Cortazar,et al.  Demonstration of a discharge pumped table-top soft X-ray laser , 1994, Proceedings of LEOS'94.

[18]  R. Germer,et al.  X-ray flash techniques , 1979 .

[19]  Eiichi Sato,et al.  Kilohertz‐range flash x‐ray generator utilizing a triode in conjunction with an extremely hot cathode , 1991 .