Dose Efficiency of Quarter-Millimeter Photon-Counting Computed Tomography: First-in-Human Results

Purpose The aim of this study was to assess the clinical feasibility, image quality, and radiation dose implications of 0.25-mm imaging mode in a cohort of humans, achieved by dividing the photon-counting detector (PCD) size in half compared with standard-resolution photon-counting computed tomography (CT) (0.5 mm). Methods In this technical feasibility study, a whole-body prototype PCD-CT scanner was studied in the 0.25 mm detector mode (measured at isocenter). A high-resolution PCD-CT protocol was first tested in phantom and canine studies in terms of image noise and spatial resolution. Then, 8 human subjects (mean age, 58 ± 8 years; 2 men) underwent axial PCD 0.25-mm scans of the brain, the thorax, and at the level of the upper left kidney. Filtered backprojection reconstruction was performed with a sharp kernel (B70) for standard-resolution and high-resolution data at 0.5-mm isotropic image voxel. High-resolution data, in addition, were reconstructed with an ultrasharp kernel (U70) at 0.25-mm isotropic voxels. Results Image reconstructions from the PCD 0.25-mm detector system led to an improvement in resolution from 9 to 18 line pairs/cm in a line pair phantom. Modulation transfer function improved from 9.5 to 15.8 line pairs/cm at 10% modulation transfer function. When fully exploiting this improvement, image noise increased by 75% compared with dose-matched 0.5-mm slice PCD standard-resolution acquisition. However, when comparing with standard-resolution data at same in-plane resolution and slice thickness, the PCD 0.25-mm detector mode showed 19% less image noise in phantom, animal, and human scans. Conclusion High-resolution photon-counting CT in humans showed improved image quality in terms of spatial resolution and image noise compared with standard-resolution photon-counting.

[1]  C. McCollough,et al.  Relationship between noise, dose, and pitch in cardiac multi-detector row CT. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  Jeffrey H Siewerdsen,et al.  Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling. , 2009, Medical physics.

[3]  Jesse Tanguay,et al.  The role of x-ray Swank factor in energy-resolving photon-counting imaging. , 2010, Medical physics.

[4]  Jeffrey H Siewerdsen,et al.  A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom. , 2013, Medical physics.

[5]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[6]  Jongduk Baek,et al.  To bin or not to bin? The effect of CT system limiting resolution on noise and detectability , 2013, Physics in medicine and biology.

[7]  Karl Stierstorfer,et al.  Photon counting CT at elevated X-ray tube currents: contrast stability, image noise and multi-energy performance , 2014, Medical Imaging.

[8]  Kazuo Awai,et al.  Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner , 2015, PloS one.

[9]  A Halaweish,et al.  A high-resolution imaging technique using a whole-body, research photon counting detector CT system , 2016, SPIE Medical Imaging.

[10]  E. Ritman,et al.  Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies , 2016, Investigative radiology.

[11]  Baiyu Chen,et al.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array , 2016, Physics in medicine and biology.

[12]  Katharina Hahn,et al.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system , 2016, Journal of medical imaging.

[13]  Amir Pourmorteza,et al.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience. , 2016, Radiology.

[14]  S. Kappler,et al.  Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment , 2017, American Journal of Neuroradiology.

[15]  Amir Pourmorteza,et al.  Photon‐counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study , 2017, Medical physics.

[16]  Steffen Kappler,et al.  Low-dose lung cancer screening with photon-counting CT: a feasibility study , 2017, Physics in medicine and biology.

[17]  Stefan Ulzheimer,et al.  Dual-contrast agent photon-counting computed tomography of the heart: initial experience , 2017, The International Journal of Cardiovascular Imaging.

[18]  Katsuyuki Taguchi,et al.  Energy-sensitive photon counting detector-based X-ray computed tomography , 2017, Radiological Physics and Technology.

[19]  Armando Manduca,et al.  An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features , 2017, Medical physics.

[20]  Ziyue Xu,et al.  A multichannel block‐matching denoising algorithm for spectral photon‐counting CT images , 2017, Medical physics.

[21]  H. Alkadhi,et al.  Photon-Counting CT: High-Resolution Imaging of Coronary Stents , 2017, Investigative radiology.

[22]  Mohammadhadi Bagheri,et al.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results , 2017, Investigative radiology.