MR-conditional steerable needle robot for intracerebral hemorrhage removal

AbstractBackgroundIntracerebral hemorrhage (ICH) is one of the deadliest forms of stroke in the USA. Conventional surgical techniques such as craniotomy or stereotactic aspiration disrupt a large volume of healthy brain tissue in their attempts to reach the surgical site. Consequently, the surviving patients suffer from debilitating complications. MethodsWe fabricated a novel MR-conditional steerable needle robot for ICH treatment. The robot system is powered by a custom-designed high power and low-cost pneumatic motor. We tested the robot’s targeting accuracy and MR-conditionality performance, and performed phantom evacuation experiment under MR image guidance. ResultsExperiments demonstrate that the robotic hardware is MR-conditional; the robot has the targeting accuracy of 1.26 ± 1.22 mm in bench-top tests. With real-time MRI guidance, the robot successfully reached the desired target and evacuated an 11.3 ml phantom hematoma in 9 min.ConclusionMRI-guided steerable needle robotic system is a potentially feasible approach for ICH treatment by providing accurate needle guidance and intraoperative surgical outcome evaluation.

[1]  Sheng Xu,et al.  Robotic System for MRI-Guided Focal Laser Ablation in the Prostate , 2017, IEEE/ASME Transactions on Mechatronics.

[2]  Zion Tsz Ho Tse,et al.  An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention , 2014, Annals of Biomedical Engineering.

[3]  Sumeet Vadera,et al.  Stereotactic robot-assisted MRI-guided laser thermal ablation of radiation necrosis in the posterior cranial fossa: technical note. , 2016, Neurosurgical focus.

[4]  R. Cormack,et al.  Design and Fabrication of MR-Tracked Metallic Stylet for Gynecologic Brachytherapy , 2016, IEEE/ASME Transactions on Mechatronics.

[5]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[6]  Lucas Elijovich,et al.  Intracerebral Hemorrhage , 2008, Seminars in neurology.

[7]  Saikat Sengupta,et al.  Prospective real‐time head motion correction using inductively coupled wireless NMR probes , 2014, Magnetic resonance in medicine.

[8]  Wayne Luk,et al.  Abstract 18568: Interfacing Fast Multi-phase Cardiac Image Registration with MRI-based Catheter Tracking for MRI-guided Electrophysiological Ablative Procedures , 2014 .

[9]  Hao Su,et al.  A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting , 2016, Annals of Biomedical Engineering.

[10]  Zion Tsz Ho Tse,et al.  A 10-mm MR-Conditional Unidirectional Pneumatic Stepper Motor , 2015, IEEE/ASME Transactions on Mechatronics.

[11]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.

[12]  Hans-Jakob Steiger,et al.  Perfusion CT in Patients With Spontaneous Lobar Intracerebral Hemorrhage: Effect of Surgery on Perihemorrhagic Perfusion , 2012, Stroke.

[13]  Robert J. Webster,et al.  Robotic intracerebral hemorrhage evacuation: An in-scanner approach with concentric tube robots , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[14]  Thomas Schneider,et al.  Match-study of statin therapy in spontaneous intracerebral hemorrhage: is the discontinuation reasonable? , 2016, Journal of neurosurgical sciences.

[15]  Daniel E. Whitney,et al.  Resolved Motion Rate Control of Manipulators and Human Prostheses , 1969 .

[16]  Keith D. Paulsen,et al.  In vivo quantification of a homogeneous brain deformation model for updating preoperative images during surgery , 2000, IEEE Transactions on Biomedical Engineering.

[17]  Robert J. Webster,et al.  Characterization and Control of a Pneumatic Motor for MR-Conditional Robotic Applications , 2017, IEEE/ASME Transactions on Mechatronics.

[18]  F A Jolesz Future perspectives in intraoperative imaging. , 2003, Acta neurochirurgica. Supplement.

[19]  Wayne Luk,et al.  MRI-based visual and haptic catheter feedback: simulating a novel system's contribution to efficient and safe MRI-guided cardiac electrophysiology procedures , 2014, Journal of Cardiovascular Magnetic Resonance.

[20]  Robert J. Webster,et al.  Debulking From Within: A Robotic Steerable Cannula for Intracerebral Hemorrhage Evacuation , 2013, IEEE Transactions on Biomedical Engineering.

[21]  Garnette R Sutherland,et al.  Advancing neurosurgery with image-guided robotics. , 2009, Journal of neurosurgery.

[22]  Robert J. Webster,et al.  A 3-D Volume Coverage Path Planning Algorithm With Application to Intracerebral Hemorrhage Evacuation , 2016, IEEE Robotics and Automation Letters.

[23]  A. Villringer,et al.  Stroke Magnetic Resonance Imaging Is Accurate in Hyperacute Intracerebral Hemorrhage: A Multicenter Study on the Validity of Stroke Imaging , 2004, Stroke.

[24]  R. Cormack,et al.  Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy. , 2015, Medical physics.

[25]  W. Stevenson,et al.  Intra-cardiac MR imaging & MR-tracking catheter for improved MR-guided EP , 2015, Journal of Cardiovascular Magnetic Resonance.

[26]  J. Goodship,et al.  Centiles for adult head circumference. , 1992, Archives of disease in childhood.

[27]  Carmelo Anile,et al.  Surgical treatment of primary supratentorial intracerebral hemorrhage in stuporous and comatose patients , 2002, Neurological research.

[28]  Jaydev P. Desai,et al.  Towards a SMA-actuated Neurosurgical Intracerebral Hemorrhage Evacuation (NICHE) robot , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[29]  Charles Mougenot,et al.  MatMRI and MatHIFU: Matlab{trade mark, serif} toolboxes for real-time monitoring and control of MR-HIFU , 2012 .

[30]  Robert J. Webster,et al.  An MRI-Compatible Robot for Intracerebral Hemorrhage Removal , 2017 .