Reproducibility of anterior chamber angle measurements with anterior segment optical coherence tomography.

PURPOSE To study the reproducibility and variability of iridocorneal angle (ICA) measurements by using anterior segment optical coherence tomography (AS-OCT) by expert and nonexpert observers. METHODS Twenty-three healthy volunteers (nonexperts with a basic knowledge of ophthalmology) acquired five consecutive AS-OCT images in the enhanced anterior segment single mode in the 180° to 0° meridian of the right eyes of their peers. Two experts and the 23 nonexperts analyzed the images. The ICA software tool was used to determine the angle opening distance (AOD) and the trabecular iris surface area (TISA) at 500 and 750 μm. A random intercept model was fitted to evaluate the variability of acquiring an image. For both the experts and the nonexperts, inter- and intraobserver variability of analyzing an AS-OCT image was determined with the coefficient of variation (CV). Reproducibility was qualified by using the intraclass correlation coefficient (ICC). RESULTS There was no statistically significant difference in the variability of acquiring an image. The range of intraobserver variability in image analysis was from 9.4% to 12.5% in the experts and from 4.2% to 17.4% in the nonexperts. Interobserver variability was 10.7% in the experts and 10.2% in the nonexperts. The reproducibility was high, 0.875 and 0.942 in the experts and 0.906 in the nonexperts. CONCLUSIONS The overall reproducibility of the ICA measurements with the AS-OCT is good in open angles. Inter- and intraobserver variability showed similar mean values of reproducibility between the experts and nonexperts. The wide range of intraobserver variation in the nonexperts suggests that this group should undergo extensive instruction before routinely analyzing AS-OCT images.

[1]  J. Izatt,et al.  Anterior chamber width measurement by high-speed optical coherence tomography. , 2005, Ophthalmology.

[2]  J. Myers,et al.  Comparison of Gonioscopy and Anterior Segment Ocular Coherence Tomography in Detecting Angle Closure in Different Quadrants of the Anterior Chamber Angle , 2009 .

[3]  C. Leung,et al.  Visualization of anterior chamber angle dynamics using optical coherence tomography. , 2005, Ophthalmology.

[4]  C. Cheung,et al.  Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography , 2007, British Journal of Ophthalmology.

[5]  Tin Aung,et al.  Assessment of the scleral spur in anterior segment optical coherence tomography images. , 2008, Archives of ophthalmology.

[6]  Kyung R Sung,et al.  Characteristics and reproducibility of anterior chamber angle assessment by anterior‐segment optical coherence tomography , 2011, Acta ophthalmologica.

[7]  D. Friedman,et al.  Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography , 2010, Journal of glaucoma.

[8]  D. Friedman,et al.  Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program , 2008, British Journal of Ophthalmology.

[9]  J. Myers Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle , 2010 .

[10]  Mingguang He,et al.  Anterior chamber angle assessment techniques. , 2008, Survey of ophthalmology.

[11]  Robert Ritch,et al.  Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT. , 2007, Investigative ophthalmology & visual science.

[12]  Tin Aung,et al.  High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. , 2009, Archives of ophthalmology.

[13]  D. Friedman,et al.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. , 2008, Ophthalmology.

[14]  Joseph A Izatt,et al.  Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. , 2005, Archives of ophthalmology.

[15]  J. Dawczynski,et al.  Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.

[16]  G. Dahmen,et al.  Anterior chamber angle measurement with optical coherence tomography: Intraobserver and interobserver variability , 2006, Journal of cataract and refractive surgery.

[17]  Christopher Kai-shun Leung,et al.  Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA). , 2006, Archives of ophthalmology.

[18]  Tin Aung,et al.  Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. , 2007, Investigative ophthalmology & visual science.