Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.

Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs while reference blood samples were simultaneously withdrawn from a femoral artery in the pigs. The lungs were cubed into approximately 2 cm3 pieces (n = 1,510). Each pig heart and kidney was cubed into approximately 1-g pieces (total n = 192 and 120, respectively). The radioactivity of each organ piece and reference blood sample was determined using a scintillation counter with count rates corrected for decay, background, and spillover. Tissue samples and reference blood samples were digested with KOH and filtered and the fluorescent dye was extracted with a solvent, or the dye was extracted from lung tissue without filtering. The fluorescence of each sample was determined for each color by use of an automated spectrophotometer. Perfusion was calculated for each organ piece from both the radioactivity and fluorescence. Correlation between flow determined by radio- and fluorescent-labeled microspheres was as follows: r = 0.96 +/- 0.01 (SD) (lung, filtered, n = 588), r = 0.99 +/- 0.00 (lung, nonfiltered, n = 710), r = 0.95 +/- 0.02 (heart, filtered), and r = 0.96 +/- 0.02 (kidney, filtered). Compared with colored microspheres, methods for quantitating fluorescent-labeled microspheres are more sensitive, less labor intensive, and less expensive. Fluorescent-labeled microspheres provide a new nonradioactive method for single and repeated measurement of regional organ perfusion.

[1]  W. Hauck,et al.  Quantitating error in blood flow measurements with radioactive microspheres. , 1989, The American journal of physiology.

[2]  Y. Shinozaki,et al.  New nonradioactive microspheres and more sensitive X-ray fluorescence to measure regional blood flow. , 1992, The American journal of physiology.

[3]  J I Hoffman,et al.  Blood flow measurements with radionuclide-labeled particles. , 1977, Progress in cardiovascular diseases.

[4]  G. Vlahakes,et al.  Increased number of myocardial blood flow measurements with radionuclide-labeled microspheres. , 1984, The American journal of physiology.

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  A M Rudolph,et al.  The Circulation of the Fetus in Utero: Methods For Studying Distribution of Blood Flow, Cardiac Output And Organ Blood Flow , 1967, Circulation research.

[7]  R. Kloner,et al.  Fluorescent microspheres: a new tool for visualization of ischemic myocardium in rats. , 1986, The American journal of physiology.

[8]  K. Messmer,et al.  MIC-II - a program for the determination of cardiac output, arterio-venous shunt and regional blood flow using the radioactive microsphere method. , 1979, Computer programs in biomedicine.

[9]  K. Messmer,et al.  Methodological error and spatial variability of organ blood flow measurements using radiolabeled microspheres , 1991, Research in experimental medicine. Zeitschrift fur die gesamte experimentelle Medizin einschliesslich experimenteller Chirurgie.

[10]  Y. Fung,et al.  Effect of velocity of distribution on red cell distribution in capillary blood vessels. , 1978, The American journal of physiology.

[11]  J I Hoffman,et al.  Some sources of error in measuring regional blood flow with radioactive microspheres. , 1971, Journal of applied physiology.

[12]  D. Gann,et al.  Measurement of blood flow to the adrenal capsule, cortex and medulla in dogs after hemorrhage by fluorescent microspheres. , 1990, Journal of the autonomic nervous system.

[13]  J B Bassingthwaighte,et al.  Validity of microsphere depositions for regional myocardial flows. , 1987, The American journal of physiology.

[14]  D. Alonso,et al.  Ultrastructural characterization of the border zone surrounding early experimental myocardial infarcts in dogs. , 1981, The American journal of pathology.

[15]  J O Westgard,et al.  Use and interpretation of common statistical tests in method-comparison studies. , 1973, Clinical chemistry.

[16]  D. Hearse,et al.  'Early' ischemia and reperfusion-induced arrhythmias: antiarrhythmic effects of diltiazem in the conscious rat. , 1988, The Canadian journal of cardiology.

[17]  G. Heusch,et al.  Measurement of Regional Myocardial Blood Flow With Multiple Colored Microspheres* , 1991, Circulation.

[18]  R. Kloner,et al.  Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs. , 1988, Circulation.