Wet-Gas Flow Modeling for the Straight Section of Throat-Extended Venturi Meter

In this paper, the wet-gas flow modeling for the straight section of a throat-extended Venturi meter was studied. Based on the separated-flow theory, a flow model was presented. The relationship between the fluctuating properties of the differential pressure (DP) over the straight section and the quality of the wet-gas flow was also studied, and a flow model of the fluctuation of the DP for wet-gas metering was established. Experiments were carried out within a system pressure range of 0.26-0.86 MPa, a gas volumetric flowrate range of 80-120 m3/h, a water volumetric flowrate range of 1.3-4.5 m3/h, and a quality range of 0.07-0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the separated-flow-theory-based model was 8.82% and that of the quality calculated from the fluctuating-property-related model was 8.77%.

[1]  Zhang Tao,et al.  Venturi Wet Gas Flow Modeling Based on Homogeneous and Separated Flow Theory , 2008 .

[2]  M. Reader-Harris,et al.  Discharge coefficients of Venturi tubes with standard and non-standard convergent angles , 2001 .

[3]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[4]  H. Lemonnier,et al.  Design of a flow metering process for two-phase dispersed flows , 1996 .

[5]  Yanfeng Geng,et al.  Study on the metering characteristics of a slotted orifice for wet gas flow , 2006 .

[6]  Wuqiang Yang,et al.  Tomography for multi-phase flow measurement in the oil industry , 2005 .

[7]  Hui Li,et al.  Wet Gas Metering Using a Venturi-meter and Neural Networks , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[8]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[9]  Richard Steven,et al.  Orifice plate meter wet gas flow performance , 2009 .

[10]  Stephen Pickering,et al.  Absolute measurement of pneumatically conveyed powder using a single long throat venturi , 2007 .

[11]  Richard Steven Horizontally installed cone differential pressure meter wet gas flow performance , 2009 .

[12]  Mateusz Turkowski,et al.  Simple installation for measurement of two-phase gas–liquid flow by means of conventional single-phase flowmeters , 2004 .

[13]  Pierre Gajan,et al.  Influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical configuration , 2007 .

[14]  Masahiro Kawaji,et al.  Void fraction prediction in two-phase flow across a tube bundle , 1992 .

[15]  David S. Weaver,et al.  An improved void fraction model for two-phase cross-flow in horizontal tube bundles , 2000 .

[16]  E. S. Johansen,et al.  A PROTOTYPE WET-GAS AND MULTIPHASE FLOWMETER , 2007 .

[17]  R. N. Steven,et al.  Wet gas metering with a horizontally mounted Venturi meter , 2002 .

[18]  Lijun Xu,et al.  On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering , 2003 .