Photoacoustic (PA) imaging is a non-invasive, non-ionizing imaging technology with high optical contrast between blood and tissue, and with high sensitivity of hemoglobin concentration and oxygen saturation due to different optical absorption spectra resulting from different oxygenation of hemoglobin. Most PA imaging systems implement a nanosecond pulsed laser source as excitation source to induce PA signal, and rely on broadband amplifiers to record time-domain PA signals [1-6]. Some groups, however, have reported using modulated continuous-wave lasers as an excitation source for frequency-domain imaging [7-9]. Frequency-domain imaging offers the potential of lock-in amplification which has sensitivities as low as nV even in noise orders of magnitude higher than the signal. However, although modulated CW sources works for low cost and compact PA imaging, it does not satisfy thermal and stress confinement conditions required for optimal PA signal strength. Here, we investigate a PA methodology using pulsed fiber lasers as excitation laser source combined with lock-in amplification technology. For comparison, we also studied time-domain PA methodology. Phantom studies show that signal-to-noise ratio (SNR) obtained with frequency domain PA imaging is significantly more sensitive than that obtained using time-domain PA imaging when the laser pulse repetition rate (PRR) matches the bandwidth of ultrasound transducer. Therefore, high sensitive PA imaging technology using pulsed fiber laser sources with lock-in amplification may potentially greatly extend the depth of PA imaging.
[1]
Wei Shi,et al.
Real-time handheld optical-resolution photoacoustic microscopy.
,
2011,
Optics express.
[2]
Wei Shi,et al.
In vivo dynamic process imaging using real-time optical-resolution photoacoustic microscopy
,
2013,
Journal of biomedical optics.
[3]
Lihong V. Wang,et al.
Photoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser.
,
2008,
Journal of biomedical optics.
[4]
Wei Shi,et al.
In vivo near-realtime volumetric optical-resolution photoacoustic microscopy using a high-repetition-rate nanosecond fiber-laser.
,
2011,
Optics express.
[5]
R. Zemp,et al.
Label-free in vivo fiber-based optical-resolution photoacoustic microscopy.
,
2011,
Optics letters.
[6]
Zhixing Xie,et al.
Laser-scanning optical-resolution photoacoustic microscopy.
,
2009,
Optics letters.
[7]
Da Xing,et al.
Simultaneous optical absorption and viscoelasticity imaging based on photoacoustic lock-in measurement.
,
2014,
Optics letters.
[8]
Hanli Liu,et al.
A cost-efficient frequency-domain photoacoustic imaging system.
,
2013,
American journal of physics.
[9]
Lihong V. Wang,et al.
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries.
,
2008,
Optics letters.