Effect of local limb temperature on pulse oximetry and the Plethysmographic pulse wave

We attempted to evaluate prospectively local thermoregulatory vasoconstriction and vasodilatation in 15 volunteers by means of pulse oximetry and plethysmography as measured by a finger tip-pulse oximeter. Recent studies [1] concluded that the plethysmo time interval (PTI) between the QRS complex on ECG and the upstroke of the Plethysmographic wave of the pulse oximeter is useful in evaluating the peripheral circulatory status. Venous (both Vv cubitae) blood samples for determination of SvO2 were drawn, as well as pulse oximetry SpO2 oxygen saturation measurements and calculation of PTI were performed under conditions of normothermia, hypothermia and hyperthermia, before and after immersing the hands of the volunteers in a cold (15 °C) and warm (45 °C) waterbath. Two pulse oximeters simultaneously were used, one for each hand, in order to check to which extent SpO2, SvO2 and PTI might be influenced by gross limb temperature changes. Our results show that during local hyperthermia SpO2 significantly decreased and during local hypothermia SpO2 increased after immersing the one hand in a warm waterbath and the other hand in a cold waterbath at the same time. The peripheral SvO2 significantly increased in the warm hand and decreased in the cold hand. PTI remained unchanged after exposure to either a cold or a warm waterbath. The possibility of technical causes for the SpO2 changes were eliminated. Finger-tip pulse oximetry SpO2 readings change with limb temperature. The change in venous oxygen saturation can be explained by temperature dependent arteriovenous shunts in the periphery. The observed change in SpO2 probably reflects altered transmission of arterial pulsations to venous blood in the finger.

[1]  A. Shore,et al.  The effect of rapid local cooling on human finger nailfold capillary blood pressure and blood cell velocity. , 1994, The Journal of physiology.

[2]  K. Arakawa,et al.  Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography , 1986, Anesthesia and analgesia.

[3]  J. Kelleher,et al.  The penumbra effect: vasomotion-dependent pulse oximeter artifact due to probe malposition. , 1989, Anesthesiology.

[4]  R. K. Webb,et al.  A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion , 1991, Anaesthesia.

[5]  J. Kaplan,et al.  The Pulse Oximeter: A Non-invasive Monitor of Oxygenation during Thoracic Surgery , 1986, The Thoracic and cardiovascular surgeon.

[6]  H Pälve Comparison of reflection and transmission pulse oximetry after open‐heart surgery , 1992, Critical care medicine.

[7]  L Tarassenko,et al.  Temperature dependence of led and its theoretical effect on pulse oximetry. , 1991, British journal of anaesthesia.

[8]  H. Nishida,et al.  Monitoring Neonatal Peripheral Circulation by Electrocardiogram-to-Oximeter Pulse Velocity , 1993, Pediatric Research.

[9]  Heikki Palve,et al.  Accuracy of three pulse oximeters at low cardiac index and peripheral temperature , 1991, Critical care medicine.

[10]  M. Sharkawy,et al.  Evaluation of a pulse oximeter during profound hypothermia. An assessment of the Biox 3700 during induction of hypothermia before cardiac surgery in paediatric patients , 1990, International journal of clinical monitoring and computing.

[11]  T. Heier,et al.  Thermoregulatory vasoconstriction during isoflurane anesthesia minimally decreases cutaneous heat loss. , 1992, Anesthesiology.

[12]  R. Buist,et al.  Pulse oximetry and postoperative hypothermia , 1988, Anaesthesia.

[13]  J. Whitwam,et al.  The accuracy of pulse oximeters , 1988, Anaesthesia.

[14]  D. Sessler,et al.  Thermoregulatory Vasoconstriction During Propofol/Nitrous Oxide Anesthesia in Humans: Threshold and Oxyhemoglobin Saturation , 1992, Anesthesia and analgesia.

[15]  C. Reilly,et al.  An evaluation of the effect of vasodilatation on oxygen saturations measured by pulse oximetry and venous blood gas analysis , 1993, Anaesthesia.