First-arrival traveltime sound speed inversion with a priori information.

PURPOSE A first-arrival travel-time sound speed algorithm presented by Tarantola [Inverse Problem Theory and Methods for Model Parameter Estimation (SIAM, Philadelphia, PA, 2005)] is adapted to the medical ultrasonics setting. Through specification of a covariance matrix for the object model, the algorithm allows for natural inclusion of physical a priori information of the object. The algorithm's ability to accurately and robustly reconstruct a complex sound speed distribution is demonstrated on simulation and experimental data using a limited aperture. METHODS The algorithm is first demonstrated generally in simulation with a numerical breast phantom imaged in different geometries. As this work is motivated by the authors' limited aperture dual sided ultrasound breast imaging system, experimental data are acquired with a Verasonics system with dual, 128 element, linear L7-4 arrays. The transducers are automatically calibrated for usage in the eikonal forward model.A priori information such as knowledge of correlated regions within the object is obtained via segmentation of B-mode images generated from synthetic aperture imaging. RESULTS As one illustration of the algorithm's facility for inclusion ofa priori information, physically grounded regularization is demonstrated in simulation. The algorithm's practicality is then demonstrated through experimental realization in limited aperture cases. Reconstructions of sound speed distributions of various complexity are improved through inclusion of a priori information. The sound speed maps are generally reconstructed with accuracy within a few m/s. CONCLUSIONS This paper demonstrates the ability to form sound speed images using two opposed commercial linear arrays to mimic ultrasound image acquisition in the compressed mammographic geometry. The ability to create reasonably good speed of sound images in the compressed mammographic geometry allows images to be readily coregistered to tomosynthesis image volumes for breast cancer detection and characterization studies.

[1]  D. A. Palmer,et al.  High‐speed data acquisition in a diffraction tomography system employing large‐scale toroidal arrays , 1997 .

[2]  Cuiping Li,et al.  Breast Imaging Using Transmission Ultrasound: Reconstructing Tissue Parameters of Sound Speed and Attenuation , 2008, 2008 International Conference on BioMedical Engineering and Informatics.

[3]  M. Verweij,et al.  An iterative method for the computation of nonlinear, wide-angle, pulsed acoustic fields of medical diagnostic transducers. , 2010, The Journal of the Acoustical Society of America.

[4]  Youli Quan,et al.  Sound-speed tomography using first-arrival transmission ultrasound for a ring array , 2007, SPIE Medical Imaging.

[5]  F L Bookstein,et al.  Assessment of ultrasonic computed tomography in symptomatic breast patients by discriminant analysis. , 1989, Ultrasound in medicine & biology.

[6]  Fong Ming Hooi,et al.  Dual sided automated ultrasound system in the mammographic geometry , 2011, 2011 IEEE International Ultrasonics Symposium.

[7]  Koen W A van Dongen,et al.  A full vectorial contrast source inversion scheme for three-dimensional acoustic imaging of both compressibility and density profiles. , 2007, The Journal of the Acoustical Society of America.

[8]  Philip A. Nelson,et al.  Optimal regularisation for acoustic source reconstruction by inverse methods , 2004 .

[9]  Aly A. Farag,et al.  MultiStencils Fast Marching Methods: A Highly Accurate Solution to the Eikonal Equation on Cartesian Domains , 2007, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[10]  Haijiang Zhang,et al.  An improved automatic time-of-flight picker for medical ultrasound tomography. , 2009, Ultrasonics.

[11]  Martin Vetterli,et al.  Robust ultrasound travel-time tomography using the bent ray model , 2010, Medical Imaging.

[12]  Michael P. Andre,et al.  Pre-Clinical Experience with Full-Wave Inverse-Scattering for Breast Imaging , 2008 .

[13]  Bo Zhao,et al.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach. , 2008, Medical physics.

[14]  Per Christian Hansen,et al.  Sound source reconstruction using inverse boundary element calculations. , 2003, The Journal of the Acoustical Society of America.

[15]  N. Duric,et al.  In vivo breast sound-speed imaging with ultrasound tomography. , 2009, Ultrasound in medicine & biology.

[16]  Jun Chen,et al.  Inverse scattering and refraction corrected reflection for breast cancer imaging , 2010, Medical Imaging.

[17]  M. Helvie,et al.  Multi-modality 3D breast imaging with X-Ray tomosynthesis and automated ultrasound , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  Xuelong Li,et al.  A novel alternative algorithm for limited angle tomography , 2011, 2011 18th IEEE International Conference on Image Processing.

[19]  Zhixing Xie,et al.  Photoacoustic imaging for deep targets in the breast using a multichannel 2D array transducer , 2011, BiOS.

[20]  Francesco Simonetti,et al.  Transmission and Reflection Diffraction Tomography in Breast Imaging , 2008, 2008 International Conference on BioMedical Engineering and Informatics.

[21]  Matti Lassas,et al.  Wavelet-based reconstruction for limited-angle X-ray tomography , 2006, IEEE Transactions on Medical Imaging.

[22]  Philip A. Nelson,et al.  ESTIMATION OF ACOUSTIC SOURCE STRENGTH BY INVERSE METHODS: PART II, EXPERIMENTAL INVESTIGATION OF METHODS FOR CHOOSING REGULARIZATION PARAMETERS , 2000 .

[23]  Neb Duric,et al.  Breast ultrasound tomography: bridging the gap to clinical practice , 2012, Medical Imaging.

[24]  P L Carson,et al.  Ultrasonic computed tomography of the breast. Improvement of image quality by use of cross-correlation time-of-flight and phase-insensitive attenuation measurements. , 1984, Radiology.

[25]  Mark A. Anastasio,et al.  An Imaging Model Incorporating Ultrasonic Transducer Properties for Three-Dimensional Optoacoustic Tomography , 2011, IEEE Transactions on Medical Imaging.