Thermoelastic Dissipation in Etch-Hole Filled Lamé Bulk-Mode Silicon Microresonators

The perforation of a Lamé bulk-mode silicon mechanical resonator via uniformly distributed etch holes has been observed to drastically reduce the quality factor by over 90%. The cause of this sharp drop remains largely unknown. A high is important, while etch holes are commonly used in the fabrication of resonators. This letter traces the cause to thermoelastic dissipation through the use of finite-element analysis based on coupled thermoelastic equations. The results from the analysis are well corroborated by data from measurements of fabricated silicon-on-insulator devices.

[1]  C. Nguyen,et al.  MEMS technology for timing and frequency control , 2005, Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, 2005..

[2]  L. C. Shao,et al.  Effect of etch holes on quality factor of bulk-mode micromechanical resonators , 2008 .

[3]  Thomas W. Kenny,et al.  Multimode thermoelastic dissipation , 2009 .

[4]  J. Kiihamaki,et al.  Square-extensional mode single-crystal silicon micromechanical resonator for low-phase-noise oscillator applications , 2004, IEEE Electron Device Letters.

[5]  T. Kenny,et al.  Engineering MEMS Resonators With Low Thermoelastic Damping , 2006, Journal of Microelectromechanical Systems.

[6]  Tomi Mattila,et al.  Analysis of vibration modes in a micromechanical square-plate resonator , 2008 .

[7]  F. Ayazi,et al.  Effect of phonon interactions on limiting the f.Q product of micromechanical resonators , 2009, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference.