High peak SAR exposure unit with tight exposure and environmental control for in vitro experiments at 1800 MHz
暂无分享,去创建一个
N. Kuster | T. Samaras | W. Oesch | T. Samaras | N. Kuster | J. Schuderer | W. Oesch | D. Spat | J. Schuderer | D. Spat | N. Kuster | Denis Spät
[1] L Laval,et al. A new in vitro exposure device for the mobile frequency of 900 MHz. , 2000, Bioelectromagnetics.
[2] 国際非電離放射線防護委員会. ICNIRP statement on the "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)". , 2009, Health physics.
[3] N Kuster,et al. Design, optimization, realization, and analysis of an in vitro system for the exposure of embryonic stem cells at 1.71 GHz. , 2000, Bioelectromagnetics.
[4] W. R. Adey,et al. Exposure of nerve growth factor-treated PC12 rat pheochromocytoma cells to a modulated radiofrequency field at 836.55 MHz: effects on c-jun and c-fos expression. , 1997, Bioelectromagnetics.
[5] Niels Kuster,et al. Millimeter-resolution E-field probe for isotropic measurement in lossy media between 100 MHz and 20 GHz , 2000, IEEE Trans. Instrum. Meas..
[6] N Kuster,et al. Basis for optimization of in vitro exposure apparatus for health hazard evaluations of mobile communications , 2001, Bioelectromagnetics.
[7] W F Pickard,et al. The radial transmission line as a broad-band shielded exposure system for microwave irradiation of large numbers of culture flasks. , 1999, Bioelectromagnetics.
[8] N. Kuster,et al. In vitro exposure systems for RF exposures at 900 MHz , 2004, IEEE Transactions on Microwave Theory and Techniques.
[9] P Regli,et al. Electromagnetic and heat transfer computations for non-ionizing radiation dosimetry. , 2000, Physics in medicine and biology.
[10] Dosimetry considerations in far field microwave exposure of mammalian cells. , 1988, Physiological chemistry and physics and medical NMR.
[11] N. Kuster,et al. Effect of the meniscus at the solid/liquid interface on the SAR distribution in Petri dishes and flasks , 2003, Bioelectromagnetics.
[12] D Krause,et al. Role of modulation on the effect of microwaves on ornithine decarboxylase activity in L929 cells. , 1997, Bioelectromagnetics.
[13] Barry N. Taylor,et al. Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .
[14] J. Mcnamee,et al. Cylindrical waveguide applicator for in vitro exposure of cell culture samples to 1.9‐GHz radiofrequency fields , 2002, Bioelectromagnetics.
[15] N Kuster,et al. Recommended minimal requirements and development guidelines for exposure setups of bio-experiments addressing the health risk concern of wireless communications. , 2000, Bioelectromagnetics.