Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.

PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam delivered by pencil-beam scanning, a 60 MeV fixed proton beam and an Elekta SL25 6 MeV electron beam. Reference dosimetry was performed using a FC65-G chamber (Elekta beam), a PPC05 (IBA beam) and both Markus 1916 and PPC40 Roos ion-chambers (60 MeV proton beam). Calibration curves of the radiochromic film dosimetry system were acquired and compared within a dose range of 0.4-10 Gy. An uncertainty budget was estimated on films irradiated by Elekta SL25 by measuring intra-film and inter-film reproducibility and uniformity; scanner uniformity and reproducibility; room light and film reading delay influences. RESULTS The global uncertainty on acquired optical densities was within 0.55% and could be reduced to 0.1% by placing films consistently at the center of the scanner. For all beam types, the calibration curves are within uncertainties of measured dose and optical densities. The total uncertainties on calibration curve due to film reading and fitting were within 1.5% for photon and proton beams. For electrons, the uncertainty was within 2% for dose superior to 0.8 Gy. CONCLUSIONS The low combined uncertainty observed and low beam and energy-dependence make EBT3 suitable for dosimetry in various applications.

[1]  Oliver Jäkel,et al.  Dosimetric properties of Gafchromic® EBT films in monoenergetic medical ion beams , 2010, Physics in medicine and biology.

[2]  Martin J Butson,et al.  Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range. , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[3]  J. Rownd,et al.  Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. , 2002, Medical physics.

[4]  D. Bonnett,et al.  Code of practice for clinical proton dosimetry. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[6]  D. Bonnett,et al.  Supplement to the code of practice for clinical proton dosimetry. ECHED (European Clinical Heavy Particle Dosimetry Group). , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  Nada Tomic,et al.  Optimizing the dynamic range extension of a radiochromic film dosimetry system. , 2009, Medical physics.

[8]  Dietmar Georg,et al.  Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance , 2007, Physics in medicine and biology.

[9]  H. Huizenga,et al.  NCS Report 5: Code of practice for the dosimetry of high-energy electron beams , 1986 .

[10]  Erik Grusell,et al.  Reference dosimetry in a scanned pulsed proton beam using ionisation chambers and a Faraday cup , 2008, Physics in medicine and biology.

[11]  M. Butson,et al.  Absorption spectra variations of EBT radiochromic film from radiation exposure. , 2005, Physics in medicine and biology.

[12]  J. Medin Implementation of water calorimetry in a 180 MeV scanned pulsed proton beam including an experimental determination of kQ for a Farmer chamber , 2010, Physics in medicine and biology.

[13]  Hugo Palmans,et al.  NCS Report 18: Code of practice for the absorbed dose determination in high energy photon and electron beams , 2008 .

[14]  Lei Dong,et al.  Dosimetric accuracy of Kodak EDR2 film for IMRT verifications. , 2005, Medical physics.

[15]  Jan Seuntjens,et al.  Dosimetric properties of improved GafChromic films for seven different digitizers. , 2004, Medical physics.

[16]  M. Gillin,et al.  Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies. , 2010, Medical physics.

[17]  J J Wilkens,et al.  Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams. , 2012, Medical physics.

[18]  E. Sham,et al.  Precise radiochromic film dosimetry using a flat-bed document scanner. , 2005, Medical physics.

[19]  J. Dempsey,et al.  Analysis of various beamlet sizes for IMRT with 6 MV photons. , 2003, Medical physics.

[20]  S. Duane,et al.  A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams. , 2004, Physics in medicine and biology.

[21]  O. Jäkel,et al.  Homogeneity of Gafchromic EBT2 film. , 2010, Medical physics.

[22]  Elisa Calamia,et al.  Clinical use of EBT model Gafchromic film in radiotherapy. , 2006, Medical physics.

[23]  Oliver Jäkel,et al.  Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams , 2008, Physics in medicine and biology.

[24]  J. Tsai,et al.  Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. , 1998, International journal of radiation oncology, biology, physics.

[25]  Determination of the correction factors for different ionization chambers used for the calibration of the helical tomotherapy static beam. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  Lei Dong,et al.  Dosimetry tools and techniques for IMRT. , 2011, Medical physics.

[27]  H. Palmans,et al.  LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry , 2010, Physics in medicine and biology.

[28]  K. Forster,et al.  Dosimetric verification of a commercial inverse treatment planning system. , 1999, Physics in medicine and biology.

[29]  Oliver Jäkel,et al.  Technical Note: Homogeneity of Gafchromic® EBT2 film , 2010 .

[30]  Absolute and relative dose measurements with Gafchromic™ EBT film for high energy electron beams with different doses per pulse. , 2008, Medical physics.

[31]  J. Dempsey,et al.  TG-69: radiographic film for megavoltage beam dosimetry. , 2007, Medical physics.

[32]  Saint Louis,et al.  American Association of Physicists in Medicine , 2014 .

[33]  Hugo Palmans,et al.  Ion recombination correction in the Clatterbridge Centre of Oncology clinical proton beam , 2006, Physics in medicine and biology.

[34]  Elisa Calamia,et al.  Clinical use of EBT model Gafchromic™ film in radiotherapy. , 2006, Medical physics.

[35]  Patrick A Kupelian,et al.  Characterization and use of EBT radiochromic film for IMRT dose verification. , 2006, Medical physics.