Optimization of a Y-graft design for improved hepatic flow distribution in the fontan circulation.

Single ventricle heart defects are among the most serious congenital heart diseases, and are uniformly fatal if left untreated. Typically, a three-staged surgical course, consisting of the Norwood, Glenn, and Fontan surgeries is performed, after which the superior vena cava (SVC) and inferior vena cava (IVC) are directly connected to the pulmonary arteries (PA). In an attempt to improve hemodynamic performance and hepatic flow distribution (HFD) of Fontan patients, a novel Y-shaped graft has recently been proposed to replace the traditional tube-shaped extracardiac grafts. Previous studies have demonstrated that the Y-graft is a promising design with the potential to reduce energy loss and improve HFD. However these studies also found suboptimal Y-graft performance in some patient models. The goal of this work is to determine whether performance can be improved in these models through further design optimization. Geometric and hemodynamic factors that influence the HFD have not been sufficiently investigated in previous work, particularly for the Y-graft. In this work, we couple Lagrangian particle tracking to an optimal design framework to study the effects of boundary conditions and geometry on HFD. Specifically, we investigate the potential of using a Y-graft design with unequal branch diameters to improve hepatic distribution under a highly uneven RPA/LPA flow split. As expected, the resulting optimal Y-graft geometry largely depends on the pulmonary flow split for a particular patient. The unequal branch design is demonstrated to be unnecessary under most conditions, as it is possible to achieve the same or better performance with equal-sized branches. Two patient-specific examples show that optimization-derived Y-grafts effectively improve the HFD, compared to initial nonoptimized designs using equal branch diameters. An instance of constrained optimization shows that energy efficiency slightly increases with increasing branch size for the Y-graft, but that a smaller branch size is preferred when a proximal anastomosis is needed to achieve optimal HFD.

[1]  Robert W. Dutton,et al.  A Software Framework for Creating Patient Specific Geometric Models from Medical Imaging Data for Simulation Based Medical Planning of Vascular Surgery , 2001, MICCAI.

[2]  Charles A. Taylor,et al.  Characterization of Coherent Structures in the Cardiovascular System , 2008, Annals of Biomedical Engineering.

[3]  R. K. Kumar,et al.  Pulmonary arteriovenous malformations after cavopulmonary anastomosis , 2009, Annals of Pediatric Cardiology.

[4]  Charles Audet,et al.  A Pattern Search Filter Method for Nonlinear Programming without Derivatives , 2001, SIAM J. Optim..

[5]  Charles A. Taylor,et al.  Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics. , 2009, The Journal of thoracic and cardiovascular surgery.

[6]  Jarek Rossignac,et al.  Simulating hemodynamics of the Fontan Y-graft based on patient-specific in vivo connections. , 2013, The Journal of thoracic and cardiovascular surgery.

[7]  A. Yoganathan,et al.  Preliminary clinical experience with a bifurcated Y-graft Fontan procedure--a feasibility study. , 2012, The Journal of thoracic and cardiovascular surgery.

[8]  A. J. Booker,et al.  A rigorous framework for optimization of expensive functions by surrogates , 1998 .

[9]  Charles Audet,et al.  Mesh Adaptive Direct Search Algorithms for Constrained Optimization , 2006, SIAM J. Optim..

[10]  B. Marino,et al.  Outcomes after the Fontan procedure , 2002, Current opinion in pediatrics.

[11]  Charles Audet,et al.  Analysis of Generalized Pattern Searches , 2000, SIAM J. Optim..

[12]  A. Yoganathan,et al.  Nonlinear Power Loss During Exercise in Single-Ventricle Patients After the Fontan: Insights From Computational Fluid Dynamics , 2007, Circulation.

[13]  J GironaComas Congenital diseases of the heart: clinical-physiological considerations , 2001 .

[14]  P G Walker,et al.  Distribution of hepatic venous blood in the total cavo pulmonary connection: an in vitro study into the effects of connection geometry. , 2001, Journal of biomechanical engineering.

[15]  T. Yagihara,et al.  Redirection of hepatic venous drainage after total cavopulmonary shunt in left isomerism. , 1999, The Annals of thoracic surgery.

[16]  I. Vignon-Clementel,et al.  Three-dimensional simulations in Glenn patients: clinically based boundary conditions, hemodynamic results and sensitivity to input data. , 2011, Journal of biomechanical engineering.

[17]  F. Migliavacca,et al.  Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis. , 2003, Journal of biomechanical engineering.

[18]  Alison L. Marsden,et al.  Constrained optimization of an idealized Y-shaped baffle for the Fontan surgery at rest and exercise , 2010 .

[19]  O. SIAMJ.,et al.  ON THE CONVERGENCE OF PATTERN SEARCH ALGORITHMS , 1997 .

[20]  A. Yoganathan,et al.  The total cavopulmonary connection resistance: a significant impact on single ventricle hemodynamics at rest and exercise. , 2008, American journal of physiology. Heart and circulatory physiology.

[21]  Charles A. Taylor,et al.  Effects of Exercise and Respiration on Hemodynamic Efficiency in CFD Simulations of the Total Cavopulmonary Connection , 2007, Annals of Biomedical Engineering.

[22]  F. Migliavacca,et al.  Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the Norwood procedure for hypoplastic left heart syndrome. , 2003, The Journal of thoracic and cardiovascular surgery.

[23]  A. Yoganathan,et al.  Pulmonary hepatic flow distribution in total cavopulmonary connections: extracardiac versus intracardiac. , 2011, Journal of Thoracic and Cardiovascular Surgery.

[24]  Charles Audet,et al.  A method for stochastic constrained optimization using derivative-free surrogate pattern search and collocation , 2010, J. Comput. Phys..

[25]  Steven Kang,et al.  Mechanics of end-to-end artery-to-PTFE graft anastomoses , 1998, Annals of vascular surgery.

[26]  Jeffrey A Feinstein,et al.  Regression of severe pulmonary arteriovenous malformations after Fontan revision and "hepatic factor" rerouting. , 2004, The Annals of thoracic surgery.

[27]  Alison L. Marsden,et al.  A computational framework for derivative-free optimization of cardiovascular geometries , 2008 .

[28]  W. Norwood,et al.  Lung Perfusion Patterns After Bidirectional Cavopulmonary Anastomosis (Hemi-Fontan Procedure) , 1997, Pediatric Cardiology.

[29]  Yutaka Imoto,et al.  Redirection of the Hepatic Venous Flow for the Treatment of Pulmonary Arteriovenous Malformations after Fontan Operation , 2006, Pediatric Cardiology.

[30]  T. P. Graham Cavopulmonary pathway modification in patients with heterotaxy and newly diagnosed or persistent pulmonary arteriovenous malformations after a modified Fontan operation , 2012 .

[31]  M. D. de Leval The Fontan circulation: a challenge to William Harvey? , 2005, Nature clinical practice. Cardiovascular medicine.

[32]  Josep Girona Comas Congenital diseases of the heart: clinical-physiological considerations , 2001 .

[33]  Meng Wang,et al.  Optimal Aeroacoustic Shape Design Using the Surrogate Management Framework , 2003 .

[34]  J. Hasse,et al.  Pulmonary Arteriovenous Malformations , 1994, Angiology.

[35]  Xiangrong Li,et al.  Anisotropic adaptive finite element method for modelling blood flow , 2005, Computer methods in biomechanics and biomedical engineering.

[36]  E M Pedersen,et al.  Effects of Exercise and Respiration on Blood Flow in Total Cavopulmonary Connection: A Real-Time Magnetic Resonance Flow Study , 2003, Circulation.

[37]  Thomas J. R. Hughes,et al.  Finite element modeling of blood flow in arteries , 1998 .

[38]  Christopher P. Cheng,et al.  Blood flow conditions in the proximal pulmonary arteries and vena cavae: healthy children during upright cycling exercise. , 2004, American journal of physiology. Heart and circulatory physiology.

[39]  Charles A. Taylor,et al.  A new multiparameter approach to computational simulation for Fontan assessment and redesign. , 2010, Congenital heart disease.

[40]  R Fumero,et al.  A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection. , 1996, Journal of biomechanics.

[41]  Jeanette P. Schmidt,et al.  The Simbios National Center: Systems Biology in Motion , 2008, Proceedings of the IEEE.

[42]  Alexander I. J. Forrester,et al.  Multi-fidelity optimization via surrogate modelling , 2007, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[43]  Yuri Bazilevs,et al.  Computational fluid–structure interaction: methods and application to a total cavopulmonary connection , 2009 .

[44]  A. Marsden,et al.  Hepatic blood flow distribution and performance in conventional and novel Y-graft Fontan geometries: a case series computational fluid dynamics study. , 2012, The Journal of thoracic and cardiovascular surgery.

[45]  A. Yoganathan,et al.  Introduction of a new optimized total cavopulmonary connection. , 2007, The Annals of thoracic surgery.

[46]  A. L. Marsden,et al.  Virtual surgeries in patients with congenital heart disease: a multi-scale modelling test case , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[47]  A. Yoganathan,et al.  In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging. , 2001, The Annals of thoracic surgery.

[48]  J. Gossage,et al.  Pulmonary arteriovenous malformations. A state of the art review. , 1998, American journal of respiratory and critical care medicine.

[49]  C A Taylor,et al.  Outflow boundary conditions for 3D simulations of non-periodic blood flow and pressure fields in deformable arteries , 2010, Computer methods in biomechanics and biomedical engineering.