Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI

Background Achieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. Purpose Magnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study Type Prospective observational study Subjects A spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence 3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell. Assessment We compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical Tests Wilcoxon rank-sum test between uncorrected and corrected data. Results In phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). Conclusion Our method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.

[1]  Stefan Skare,et al.  How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging , 2003, NeuroImage.

[2]  P. Basser,et al.  The b matrix in diffusion tensor echo‐planar imaging , 1997, Magnetic resonance in medicine.

[3]  M. Revenu,et al.  MRI geometric distortion: A simple approach to correcting the effects of non‐linear gradient fields , 1999, Journal of magnetic resonance imaging : JMRI.

[4]  P. Basser,et al.  Analytical Expressions for the b Matrix in NMR Diffusion Imaging and Spectroscopy , 1994 .

[5]  S Napel,et al.  Quantifying MRI geometric distortion in tissue , 1994, Magnetic resonance in medicine.

[6]  Bennett A Landman,et al.  Phantom-based field maps for gradient nonlinearity correction in diffusion imaging , 2018, Medical Imaging.

[7]  P. Batchelor,et al.  International Society for Magnetic Resonance in Medicine , 1997 .

[8]  Max A. Viergever,et al.  The adverse effect of gradient nonlinearities on diffusion MRI: From voxels to group studies , 2020, NeuroImage.

[9]  John Kornak,et al.  Gradient nonlinearity correction to improve apparent diffusion coefficient accuracy and standardization in the american college of radiology imaging network 6698 breast cancer trial , 2015, Journal of magnetic resonance imaging : JMRI.

[10]  David N. Kennedy,et al.  MRI-based anatomical model of the human head for specific absorption rate mapping , 2008, Medical & Biological Engineering & Computing.

[11]  Jeffry R Alger,et al.  The Diffusion Tensor Imaging Toolbox , 2012, The Journal of Neuroscience.

[12]  G. Marchal,et al.  On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery. , 1994, Magnetic resonance imaging.

[13]  Stamatios N. Sotiropoulos,et al.  An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging , 2016, NeuroImage.

[14]  P. Basser Inferring microstructural features and the physiological state of tissues from diffusion‐weighted images , 1995, NMR in biomedicine.

[15]  Yunhong Shu,et al.  Integrated image reconstruction and gradient nonlinearity correction , 2015, Magnetic resonance in medicine.

[16]  T E Conturo,et al.  Diffusion MRI: Precision, accuracy and flow effects , 1995, NMR in biomedicine.

[17]  Bennett A Landman,et al.  Stability of gradient field corrections for quantitative diffusion MRI , 2017, Medical Imaging.

[18]  Yunhong Shu,et al.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction. , 2015, Medical physics.

[19]  M. Caola,et al.  Solid harmonics and their addition theorems , 1978 .

[20]  L. Frank Anisotropy in high angular resolution diffusion‐weighted MRI , 2001, Magnetic resonance in medicine.

[21]  Mark Jenkinson,et al.  The minimal preprocessing pipelines for the Human Connectome Project , 2013, NeuroImage.

[22]  Christopher J. Hardy,et al.  Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging , 2013, Journal of magnetic resonance imaging : JMRI.

[23]  Martin O Leach,et al.  A complete distortion correction for MR images: I. Gradient warp correction , 2005, Physics in medicine and biology.

[24]  Wei Huang,et al.  Demonstration of nonlinearity bias in the measurement of the apparent diffusion coefficient in multicenter trials , 2016, Magnetic resonance in medicine.

[25]  Jonathan S. Lewin,et al.  Diffusion and Perfusion Magnetic Resonance Imaging , 1996, Neurology.

[26]  Julien Cohen-Adad,et al.  The Human Connectome Project and beyond: Initial applications of 300mT/m gradients , 2013, NeuroImage.

[27]  Yunhong Shu,et al.  Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction , 2018, Journal of magnetic resonance imaging : JMRI.

[28]  P. Basser,et al.  Polyvinylpyrrolidone (PVP) water solutions as isotropic phantoms for diffusion MRI studies , 2008 .

[29]  Anthony J. Stone,et al.  Properties of the regular and irregular solid harmonics , 1977 .

[30]  N J Pelc,et al.  Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imaging , 2003, Magnetic resonance in medicine.