Wireless biopotential acquisition system for portable healthcare monitoring

A complete biopotential acquisition system with an analogue front-end (AFE) chip is proposed for portable healthcare monitoring. A graphical user interface (GUI) is also implemented to display the extracted biopotential signals in real-time on a computer for patients or in a hospital via the internet for doctors. The AFE circuit defines the quality of the acquired biosignals. Thus, an AFE chip with low power consumption and a high common-mode rejection ratio (CMRR) was implemented in the TSMC 0.18-μm CMOS process. The measurement results show that the proposed AFE, with a core area of 0.1 mm2, has a CMRR of 90 dB, and power consumption of 21.6 μW. Biopotential signals of electroencephalogram (EEG), electrocardiogram (ECG) and electromyogram (EMG) were measured to verify the proposed system. The board size of the proposed system is 6 cm×2.5 cm and the weight is 30 g. The total power consumption of the proposed system is 66 mW.

[1]  Refet Firat Yazicioglu,et al.  A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems , 2007, IEEE Journal of Solid-State Circuits.

[2]  C. Van Hoof,et al.  Effect of electrode offset on the CMRR of the current balancing instrumentation amplifiers , 2005, Research in Microelectronics and Electronics, 2005 PhD.

[3]  W. Guggenbuhl,et al.  A versatile building block: the CMOS differential difference amplifier , 1987 .

[4]  F. Eatock A monolithic instrumentation amplifier with low input current , 1973 .

[5]  A. Brokaw,et al.  An improved monolithic instrumentation amplifier , 1975, IEEE Journal of Solid-State Circuits.

[6]  Viera Stopjakova,et al.  WIRELESS MEASUREMENT SYSTEM FOR NON-INVASIVE BIOMEDICAL MONITORING OF PSYCHO-PHYSIOLOGICAL PROCESSES , 2009 .

[7]  Ramon Pallàs-Areny,et al.  AC-coupled front-end for biopotential measurements , 2003, IEEE Transactions on Biomedical Engineering.

[8]  P. Merken,et al.  Integrated low-power 24-channel EEG front-end , 2005 .

[9]  A.-T. Avestruz,et al.  A 2 $\mu\hbox{W}$ 100 nV/rtHz Chopper-Stabilized Instrumentation Amplifier for Chronic Measurement of Neural Field Potentials , 2007, IEEE Journal of Solid-State Circuits.

[10]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.

[11]  H. Krabbe A high-performance monolithic instrumentation amplifier , 1971 .

[12]  Aleksey Pesterev,et al.  Bi-Fi: An Embedded Sensor/System Architecture for Remote Biological Monitoring , 2007, IEEE Transactions on Information Technology in Biomedicine.

[13]  Behzad Razavi,et al.  Design of Analog CMOS Integrated Circuits , 1999 .

[14]  Reid R. Harrison,et al.  A low-power, low-noise CMOS amplifier for neural recording applications , 2002, 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353).

[15]  Sergio Franco,et al.  Design with Operational Amplifiers and Analog Integrated Circuits , 1988 .

[16]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[17]  W.M.C. Sansen,et al.  A micropower low-noise monolithic instrumentation amplifier for medical purposes , 1987 .

[18]  Rui Escadas Martins,et al.  A CMOS IC for portable EEG acquisition systems , 1998, IEEE Trans. Instrum. Meas..

[19]  P. K. Chan,et al.  A CMOS analog front-end IC for portable EEG/ECG monitoring applications , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[20]  Amine Nait-Ali Advanced Biosignal Processing , 2009 .