Single Degree-of-Freedom Exoskeleton Mechanism Design for Thumb Rehabilitation

This paper presents the kinematic design of a spatial, 1-degree-of-freedom closed linkage to be used as an exoskeleton for thumb motion. Together with an already-designed finger mechanism, it forms a robotic device for hand therapy. The goal for the exoskeleton is to generate the desired grasping and pinching path of the thumb with one degree of freedom, rather than using a system actuating all its joints independently. In addition to the path of the thumb, additional constraints are added in order to control the position and size of the exoskeleton, reducing physical and sensory interference with the user.

[1]  E. Burdet,et al.  Robot-assisted rehabilitation of hand function. , 2010, Current opinion in neurology.

[2]  Derek G. Kamper,et al.  An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke , 2007 .

[3]  David J. Reinkensmeyer,et al.  Single degree-of-freedom exoskeleton mechanism design for finger rehabilitation , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[4]  D.J. Reinkensmeyer,et al.  Optimizing Compliant, Model-Based Robotic Assistance to Promote Neurorehabilitation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  Lung-Wen Tsai,et al.  Mechanism Design: Enumeration of Kinematic Structures According to Function , 2001 .

[6]  T. Platz,et al.  Electromechanical and robot-assisted arm training for improving arm function and activities of daily living after stroke. , 2008, The Cochrane database of systematic reviews.

[7]  Ellen M Frick,et al.  Combined Use of Repetitive Task Practice and an Assistive Robotic Device in a Patient With Subacute Stroke , 2006, Physical Therapy.

[8]  Kenneth J. Waldron,et al.  A study of overconstrained linkage geometry by solution of closure equations — Part II. Four-bar linkages with lower pair joints other than screw joints☆ , 1973 .

[9]  Gerd Hirzinger,et al.  The thumb: guidelines for a robotic design , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  D. Reinkensmeyer,et al.  Review of control strategies for robotic movement training after neurologic injury , 2009, Journal of NeuroEngineering and Rehabilitation.

[11]  Patrick van der Smagt,et al.  Movement model of a human hand based on magnetic resonance imaging (MRI) , 2010 .

[12]  Haruhisa Kawasaki,et al.  A design of fine motion assist equipment for disabled hand in robotic rehabilitation system , 2011, J. Frankl. Inst..

[13]  J. McCarthy,et al.  Kinematic Synthesis of Spatial Serial Chains Using Clifford Algebra Exponentials , 2006 .

[14]  J.A. Galvez,et al.  Some Key Problems for Robot-Assisted Movement Therapy Research: A Perspective from the University of California at Irvine , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[15]  N. Hogan,et al.  A comparison of functional and impairment-based robotic training in severe to moderate chronic stroke: a pilot study. , 2008, NeuroRehabilitation.

[16]  B. Brewer,et al.  Poststroke Upper Extremity Rehabilitation: A Review of Robotic Systems and Clinical Results , 2007, Topics in stroke rehabilitation.

[17]  Jay McCormack,et al.  Design method for a reconfigurable mechanism for finger rehabilitation , 2010, RA 2010.