Fabrication of a PMN-PT Single Crystal-Based Transcranial Doppler Transducer and the Power Regulation of Its Detection System

Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The −6 dB bandwidth of the transducer is 68.4% and the sensitivity is −17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA) measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries.

[1]  H. Hamann,et al.  Carotid endarterectomy in patients with vertebro-basilar insufficiency , 1986 .

[2]  C Marini,et al.  Reproducibility of transcranial Dopplersonography: a validation study. , 1992, Ultrasound in medicine & biology.

[3]  A. Delcker DER EINSATZ DES ULTRASCHALLS IN DER NEUROLOGISCHEN DIAGNOSTIK , 1996 .

[4]  Haosu Luo,et al.  Growth and characterization of relaxor ferroelectric PMNT single crystals , 1999 .

[5]  Weizhuo Zhong,et al.  Growth and piezoelectric properties of Pb(Mg1/3Nb2/3)O3–PbTiO3 crystals by the modified Bridgman technique , 2001 .

[6]  A. Neuhold,et al.  Transcranial Dopplersonography of the vertebro-basilar system , 2005, Acta Neurochirurgica.

[7]  H. Luo,et al.  Dependence of Dielectric Properties of 0.9Pb(Mg1/3Nb2/3)O3-0.1PbTiO3 Crystals on the Crystallographic Orientation and External Electric Field , 2005 .

[8]  R. Totaro,et al.  Transcranial Doppler evaluation of cerebral blood flow in patients with paroxysmal atrial fibrillation , 1993, The Italian Journal of Neurological Sciences.

[9]  Qifa Zhou,et al.  Piezoelectric materials for high frequency medical imaging applications: A review , 2007 .

[10]  Junhao Chu,et al.  Growth and pyroelectric properties of high Curie temperature relaxor-based ferroelectric Pb(In1∕2Nb1∕2)O3–Pb(Mg1∕3Nb2∕3)O3–PbTiO3 ternary single crystal , 2008 .

[11]  Qifa Zhou,et al.  Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer , 2009, Physics in medicine and biology.

[12]  Sylvain Ballandras,et al.  Large electromechanical coupling factor film bulk acoustic resonator with X-cut LiNbO3 layer transfer , 2009 .

[13]  Qifa Zhou,et al.  Ultrasonic Doppler measurements of blood flow velocity of rabbit retinal vessels using a 45-MHz needle transducer , 2009, Graefe's Archive for Clinical and Experimental Ophthalmology.

[14]  Qifa Zhou,et al.  High Frequency PMN-PT 1-3 Composite Transducer for Ultrasonic Imaging Application , 2010, Ferroelectrics.

[15]  Haosu Luo,et al.  The Growth and Properties of Relaxor‐Based Ferroelectric Single Crystals , 2010 .

[16]  Siu Wing Or,et al.  Temperature dependence of dielectric polarization and strain behaviors for rhombohedral PIMNT single crystal with different crystallographic orientations , 2012 .

[17]  Weiqi Wang,et al.  Cylindrically shaped ultrasonic linear array fabricated using PIMNT/epoxy 1-3 piezoelectric composite , 2013 .

[18]  Wenwu Cao,et al.  Relaxor-based ferroelectric single crystals: growth, domain engineering, characterization and applications. , 2014, Progress in materials science.