Confirmation of correct tracheal tube placement in newborn infants.

Tracheal intubation remains a common procedure during neonatal intensive care. Rapid confirmation of correct tube placement is important because tube malposition is associated with serious adverse outcomes. The current gold standard test to confirm tube position is a chest radiograph, however this is often delayed until after ventilation has commenced. Hence, point of care methods to confirm correct tube placement have been developed. The aim of this article is to review the available literature on tube placement in newborn infants. We reviewed books, resuscitation manuals and articles from 1830 to the present with the search terms "Infant, Newborn", "Endotracheal intubation", "Resuscitation", "Clinical signs", "Radiography", "Respiratory Function Tests", "Laryngoscopy", "Ultrasonography", and "Bronchoscopy". Various techniques have been studied to help clinicians assess tube placement. However, despite 85 years of clinical practice, the search for higher success rates and quicker intubation continues. Currently, chest radiography remains the gold standard test to confirm tube position. However, rigorous evaluation of new techniques is required to ensure the safety of newborn infants.

[1]  J. Carlin,et al.  Nasal CPAP or intubation at birth for very preterm infants. , 2008, The New England journal of medicine.

[2]  N. Finer,et al.  A Survey of Delivery Room Resuscitation Practices in the United States , 2006, Pediatrics.

[3]  H. Roberts An anaesthetist's contribution to the resuscitation of the newborn. , 1950, The Journal of obstetrics and gynaecology of the British Empire.

[4]  L. Kuhns,et al.  Endotracheal tube position in the infant. , 1971, The Journal of pediatrics.

[5]  D. R. Logan,et al.  First thoracic vertebral body as reference for endotracheal tube placement. , 1994, Archives of disease in childhood. Fetal and neonatal edition.

[6]  P. Dunn Dr James Blundell (1790-1878) and neonatal resuscitation. , 1989, Archives of disease in childhood.

[7]  W. Maniscalco,et al.  The use of capnography for recognition of esophageal intubation in the neonatal intensive care unit , 1995, Pediatric pulmonology.

[8]  J. Jelovsek,et al.  Accuracy of the 7-8-9 Rule for endotracheal tube placement in the neonate , 2006, Journal of Perinatology.

[9]  N. Finer,et al.  Ultrasound Confirmation of Endotracheal Tube Position in Neonates , 2012, Neonatology.

[10]  J. Robinson Respiratory recording from the oesophagus. , 1974, British medical journal.

[11]  John J. Moore,et al.  The Pediatric Disposable End-Tidal Carbon Dioxide Detector Role in Endotracheal Intubation in Newborns , 1999, Journal of Perinatology.

[12]  R. Vigneswaran,et al.  The use of a new ultra-thin fiberoptic bronchoscope to determine endotracheal tube position in the sick newborn infant. , 1981, Chest.

[13]  C. O. Kamlin,et al.  Assessment of flow waves and colorimetric CO2 detector for endotracheal tube placement during neonatal resuscitation. , 2011, Resuscitation.

[14]  J. Modell,et al.  Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory gas. , 1984, Anesthesiology.

[15]  T. Slovis,et al.  Endotracheal tubes in neonates: sonographic positioning. , 1986, Radiology.

[16]  M. Popat,et al.  Miniature screen for fibreoptic intubation using a camera. , 1997, Anaesthesia.

[17]  P. Davis,et al.  Assessment of chest rise during mask ventilation of preterm infants in the delivery room. , 2011, Resuscitation.

[18]  J. Modell,et al.  Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory gas. , 1983, Anesthesiology.

[19]  M. Weiss,et al.  Video-intuboscopic assistance is a useful aid to tracheal intubation in pediatric patients , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[20]  G. S. Rath,et al.  Flexible fiberoptic bronchoscopy. Techniques and review of 100 bronchoscopies. , 1973, Chest.

[21]  P. Davis,et al.  Assessment of tidal volume and gas leak during mask ventilation of preterm infants in the delivery room , 2010, Archives of Disease in Childhood: Fetal and Neonatal Edition.

[22]  B. Urlesberger,et al.  Erstversorgung von Neugeborenen , 2010, Monatsschrift Kinderheilkunde.

[23]  H. Mugishima,et al.  A role of end-tidal CO2 monitoring for assessment of tracheal intubations in very low birth weight infants during neonatal resuscitation at birth , 2009, Journal of perinatal medicine.

[24]  S. Kempley,et al.  Endotracheal tube length for neonatal intubation. , 2008, Resuscitation.

[25]  C. O. Kamlin,et al.  Colorimetric end-tidal carbon dioxide detectors in the delivery room: strengths and limitations. A case report. , 2005, The Journal of pediatrics.

[26]  H. Hummler,et al.  Delivery room management of very low birth weight infants in Germany, Austria and Switzerland - a comparison of protocols , 2010, European journal of medical research.

[27]  M. Bhende,et al.  End-tidal carbon dioxide changes during cardiopulmonary resuscitation after experimental asphyxial cardiac arrest. , 1996, The American journal of emergency medicine.

[28]  T. Asai Videolaryngoscopes: Do They Truly Have Roles in Difficult Airways? , 2012, Anesthesiology.

[29]  G. Berci,et al.  A Videolaryngoscopy Technique for the Intubation of the Newborn: Preliminary Report , 2009, Pediatrics.

[30]  M. Paloheimo,et al.  Capnography for Detection of Accidental Oesophageal Intubation , 1983, Acta anaesthesiologica Scandinavica.

[31]  P. Davis,et al.  Respiratory monitoring of neonatal resuscitation , 2009, Archives of Disease in Childhood: Fetal and Neonatal Edition.

[32]  G. Burton,et al.  The value of carbon dioxide monitoring during anæsthesia * , 1966, Anaesthesia.

[33]  D. Bulas,et al.  Routine chest radiographs in pediatric intensive care: a prospective study. , 1989, Pediatrics.

[34]  Peter Allen Lingle Sonographic verification of endotracheal tube position in neonates: A modified technique , 1988, Journal of clinical ultrasound : JCU.

[35]  G. A. D. da Silva,et al.  Neonatal laryngoscope intubation and the digital method: a randomized controlled trial. , 2006, The Journal of pediatrics.

[36]  K. Lui,et al.  A new system for location of endotracheal tube in preterm and term neonates. , 1991, Pediatrics.

[37]  D. Trevisanuto,et al.  The glidescope® video laryngoscope: initial experience in five neonates , 2006, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[38]  Raymond J. Ward,et al.  Tidal Volume Threshold for Colorimetric Carbon Dioxide Detectors Available for Use in Neonates , 2008, Pediatrics.

[39]  N. Finer,et al.  A randomized trial of suprasternal palpation to determine endotracheal tube position in neonates. , 2004, Resuscitation.

[40]  P. Flagg TREATMENT OF ASPHYXIA IN THE NEW-BORN: PRELIMINARY REPORT OF THE PRACTICAL APPLICATION OF MODERN SCIENTIFIC METHODS , 1928 .

[41]  J. S. Denson,et al.  A flexible fiber optic laryngoscope. , 1972, JAMA.

[42]  N. Finer,et al.  Neonatal intubation: success of pediatric trainees. , 2005, The Journal of pediatrics.

[43]  M. L. Tochen Orotracheal intubation in the newborn infant: a method for determining depth of tube insertion. , 1979, The Journal of pediatrics.

[44]  P. Davis,et al.  Heart rate changes during resuscitation of newly born infants <30 weeks gestation: an observational study , 2010, Archives of Disease in Childhood: Fetal and Neonatal Edition.

[45]  R. Ward,et al.  Esophageal Intubation: A Review of Detection Techniques , 1986, Anesthesia and analgesia.

[46]  Abhik Das,et al.  Early CPAP versus surfactant in extremely preterm infants. , 2010, The New England journal of medicine.

[47]  M. Escobedo,et al.  Proficiency of pediatric residents in performing neonatal endotracheal intubation. , 2003, Pediatrics.

[48]  D. Tingay,et al.  A comparison of different bedside techniques to determine endotracheal tube position in a neonatal piglet model , 2013, Pediatric pulmonology.

[49]  R. Higgins,et al.  Fiberoptic bronchoscopy in the treatment of intubated neonates. , 1989, American journal of diseases of children.

[50]  L. Nogee,et al.  Use of Capnography in the Delivery Room for Assessment of Endotracheal Tube Placement , 2001, Journal of Perinatology.

[51]  N. Finer,et al.  Flexible endoscopic intubation of the neonate , 1992, Pediatric pulmonology.

[52]  S. Deshpande,et al.  Foot length, an accurate predictor of nasotracheal tube length in neonates , 2001, Archives of disease in childhood. Fetal and neonatal edition.

[53]  M. Hazinski,et al.  Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. , 2010, Circulation.

[54]  M. O'Reilly,et al.  Monitoring during Neonatal Transport , 2012 .

[55]  Peter G Davis,et al.  Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects , 2006, Pediatrics.

[56]  V. Politi,et al.  Resuscitation of the newborn , 1957, Canadian Anaesthetists' Society journal.

[57]  D. Hatch,et al.  Estimation of nasotracheal tube length in infants and children. , 1987, British journal of anaesthesia.

[58]  Dawn Dillman,et al.  Video Laryngoscopy with the Macintosh Video Laryngoscope in Simulated Prehospital Scenarios by Paramedic Students , 2009, Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors.

[59]  D. Penning,et al.  Endotracheal tube malposition within the pediatric population: a common event despite clinical evidence of correct placement , 2008, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[60]  L. Kuhns,et al.  Endotracheal tube placement in infants determined by suprasternal palpation: a new technique. , 1975, Pediatrics.

[61]  P. Davis,et al.  Assessment of gas flow waves for endotracheal tube placement in an ovine model of neonatal resuscitation. , 2010, Resuscitation.

[62]  N. Finer,et al.  Duration of intubation attempts during neonatal resuscitation. , 2004, The Journal of pediatrics.

[63]  R. Neumar,et al.  Part 9: post-cardiac arrest care: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. , 2010, Circulation.

[64]  F. Mimouni,et al.  Orotracheal tube insertion in extremely low birth weight infants. , 2009, The Journal of pediatrics.

[65]  A. Bush,et al.  Use of Bedside Ultrasonography for Endotracheal Tube Placement in Pediatric Patients: A Feasibility Study , 2007, Pediatrics.

[66]  H. Gurnaney,et al.  A Prospective Randomized Equivalence Trial of the GlideScope Cobalt® Video Laryngoscope to Traditional Direct Laryngoscopy in Neonates and Infants , 2012, Anesthesiology.

[67]  P. Davis,et al.  Use of supplementary equipment for resuscitation of newborn infants at tertiary perinatal centres in Australia and New Zealand , 2005, Acta paediatrica.

[68]  E. Rowbotham,et al.  Anæsthetics in the Plastic Surgery of the Face and Jaws , 1921, Proceedings of the Royal Society of Medicine.