Radiofrequency Fields and SAR for Transverse Electromagnetic (TEM) Surface Coils

The ability to predict transmit characteristics in vivo is an important and necessary tool for the development and understanding of radiofrequency (RF) coils in high-field magnetic resonance imaging systems. Accurate simulation provides the coil developer a means to determine the RF fields produced by the coils and the RF power deposition in the sample/subject. This is especially important currently where arrays of multielement surface coils are proposed to maximize transmitted RF magnetic fields. Finite difference time domain (FDTD) simulations provide detailed RF field information for single and multielement RF coils and on field optimization techniques such as B1+ shimming. Confidence in simulations guides the development of future RF coils and optimization strategies. This article discusses the basics of the FDTD methodology and outlines important details of modeling RF coils. Keywords: RF; surface coil; SAR; TEM; shimming; FDTD; high-field MRI

[1]  Michael B. Smith,et al.  Central brightening due to constructive interference with, without, and despite dielectric resonance , 2005, Journal of magnetic resonance imaging : JMRI.

[2]  K. Yee Numerical solution of initial boundary value problems involving maxwell's equations in isotropic media , 1966 .

[3]  T. Ibrahim A numerical analysis of radio-frequency power requirements in magnetic resonance imaging experiment , 2004, IEEE Transactions on Microwave Theory and Techniques.

[4]  Vasily L Yarnykh,et al.  Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field , 2007, Magnetic resonance in medicine.

[5]  Michael B. Smith,et al.  Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil , 2001, Magnetic resonance in medicine.

[6]  Jullie W Pan,et al.  High frequency volume coils for clinical NMR imaging and spectroscopy , 1994, Magnetic resonance in medicine.

[7]  J. Pauly,et al.  Saturated double‐angle method for rapid B1+ mapping , 2006, Magnetic resonance in medicine.

[8]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[9]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[10]  J. Thomas Vaughan,et al.  Ultra High Field MRI: High-Frequency Coils , 2006 .

[11]  Steen Moeller,et al.  B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil , 2005, Magnetic resonance in medicine.

[12]  F. Wiesinger,et al.  B1 mapping by Bloch‐Siegert shift , 2010, Magnetic resonance in medicine.

[13]  Allen Taflove,et al.  Application of the Finite-Difference Time-Domain Method to Sinusoidal Steady-State Electromagnetic-Penetration Problems , 1980, IEEE Transactions on Electromagnetic Compatibility.

[14]  K. Uğurbil,et al.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.

[15]  G. Metzger,et al.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurements , 2008, Magnetic resonance in medicine.

[16]  L. Bolinger,et al.  Mapping of the Radiofrequency Field , 1993 .

[17]  K. Foster,et al.  RF-field interactions with biological systems: Electrical properties and biophysical mechanisms , 1980, Proceedings of the IEEE.

[18]  L.L. Libby,et al.  Special Aspects of Balanced Shielded Loops , 1946, Proceedings of the IRE.

[19]  J T Vaughan,et al.  High resolution neuroimaging at 4.1T. , 1995, Magnetic resonance imaging.

[20]  J. L. Young Propagation in linear dispersive media: finite difference time-domain methodologies , 1995 .

[21]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[22]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[23]  Peter Andersen,et al.  9.4T human MRI: Preliminary results , 2006, Magnetic resonance in medicine.

[24]  P B Roemer,et al.  Volume imaging with MR phased arrays , 1991, Magnetic resonance in medicine.

[25]  Steen Moeller,et al.  Performance of external and internal coil configurations for prostate investigations at 7 T , 2010, Magnetic resonance in medicine.

[26]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[27]  D. Hoult,et al.  The field dependence of NMR imaging. I. Laboratory assessment of signal‐to‐noise ratio and power deposition , 1986, Magnetic resonance in medicine.