Dampness and airway inflammation and systemic symptoms in office building workers.

To evaluate dose-response relationships between airway inflammation/systemic symptoms and dampness exposure, we conducted a self-reported questionnaire study on risk factors among 1237 employees in 19 air-conditioned office buildings in the Taipei area. The odds ratio for eye irritation was 1.34 when either stuffy odor or mold was present in the buildings. The odds ratio increased to 1.72 when both stuffy odor and mold were present, to 3.14 when water damage was also present, and to 5.03 when four dampness exposure factors were present. Dampness in the building had a dose-response effect on eye irritation, cough, and lethargy/fatigue.

[1]  Jan Sundell,et al.  A Prevalence Study Of The Sick Building Syndrome (SBS) And Facial Skin Symptoms In Office Workers , 1993 .

[2]  G. Abbritti,et al.  High prevalence of sick building syndrome in a new air-conditioned building in Italy. , 1992, Archives of environmental health.

[3]  Bert Brunekreef,et al.  Health and Indoor Climate Complaints of 7043 office Workers in 61 Buildings in the Netherlands , 1992 .

[4]  B. Brunekreef,et al.  Damp housing and adult respiratory symptoms , 1992, Allergy.

[5]  C. Hsu,et al.  Indoor pollution and sick building syndrome symptoms among workers in day-care centers. , 1997, Archives of environmental health.

[6]  C S Li,et al.  Dampness and respiratory symptoms among workers in daycare centers in a subtropical climate. , 1997, Archives of environmental health.

[7]  M J Hodgson,et al.  Symptoms and microenvironmental measures in nonproblem buildings. , 1991, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[8]  Alan Hedge,et al.  Work-related illness in offices: A proposed model of the “sick building syndrome” , 1989 .

[9]  Mucosal irritation and thermal comfort among occupants of an office building , 1993 .

[10]  P. Verkasalo,et al.  Magnetic fields and leukemia--risk for adults living close to power lines. , 1996, Scandinavian journal of work, environment & health.

[11]  Mark J. Mendell,et al.  Non‐Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature , 1993 .

[12]  R. Burnett,et al.  Adverse health effects among adults exposed to home dampness and molds. , 1991, The American review of respiratory disease.

[13]  D Norbäck,et al.  Indoor air quality and personal factors related to the sick building syndrome. , 1990, Scandinavian journal of work, environment & health.

[14]  B. V. Pedersen,et al.  Influence of personal characteristics, job-related factors and psychosocial factors on the sick building syndrome. Danish Indoor Climate Study Group. , 1989, Scandinavian journal of work, environment & health.

[15]  D. Norbäck,et al.  Environmental, occupational, and personal factors related to the prevalence of sick building syndrome in the general population. , 1991, British journal of industrial medicine.

[16]  K. Kreiss,et al.  The epidemiology of building-related complaints and illness. , 1989, Occupational medicine.

[17]  C. S. Li,et al.  Home dampness and childhood respiratory symptoms in a subtropical climate. , 1996, Archives of environmental health.

[18]  P. Skov,et al.  Influence of indoor climate on the sick building syndrome in an office environment. The Danish Indoor Climate Study Group. , 1990, Scandinavian journal of work, environment & health.

[19]  Sick building syndrome in a Canadian office complex. , 1993, Archives of environmental health.

[20]  J J Jaakkola,et al.  Type of ventilation system in office buildings and sick building syndrome. , 1995, American journal of epidemiology.

[21]  A. Smith,et al.  Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies. , 1990, American journal of public health.

[22]  Alan Hedge,et al.  Individual and Occupational Correlates of the Sick Building Syndrome , 1995 .