Battery ripple current reduction in a three-phase interleaved dc-dc converter for 5kW battery charger

This paper proposes a battery ripple current reduction method and design of three-phase interleaved dc-dc converter for 5kW battery charger, which is applied for stabilizing a wind-power generating system. The charger consists of three-phase interleaved dc-dc converter, which is the interface of batteries and DC link, and a grid connected inverter. Lead-acid battery is modeled in the first order R-C model by MATLAB/Simulink and battery parameters are measured by the pulsed current and constant current discharge test. The battery is connected to the three-phase interleaved dc-dc converter in order for reduction of ripple current to 8% from 32.5%, increase of battery lifetime and reduction of total size of inductors. The ripple current is further reduced to 2% from 8% by connecting a filter capacitor and design rule of filter capacitor is analyzed. The controller for charging and discharging mode is designed and the proposed reduction methods of battery ripple currents are verified in a 5kW charger.

[1]  Dehong Xu,et al.  Modeling and control of aggregated Super-Capacitor Energy Storage system for wind power generation , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[2]  Xunwei Yu,et al.  Modeling and control of an integrated wind power generation and energy storage system , 2009, 2009 IEEE Power & Energy Society General Meeting.

[3]  L.-A. Dessaint,et al.  A Generic Battery Model for the Dynamic Simulation of Hybrid Electric Vehicles , 2007, 2007 IEEE Vehicle Power and Propulsion Conference.

[4]  J. Allen Byrne An update on the codes, standards and guides applicable to stationary lead-acid batteries , 2010, Intelec 2010.

[5]  T. M. Jahns,et al.  System identification-based lead-acid battery online monitoring system for electric vehicles , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[6]  Hirofumi Akagi,et al.  A 6-kW, 2-kWh Lithium-Ion battery energy storage system using a bidirectional isolated DC-DC converter , 2010, The 2010 International Power Electronics Conference - ECCE ASIA -.

[7]  David M. Otten,et al.  High efficiency power factor correction using interleaving techniques , 1992, [Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition.

[8]  Andreas Jossen,et al.  Methods for state-of-charge determination and their applications , 2001 .

[9]  D.M. Vilathgamuwa,et al.  Energy storage systems in distributed generation schemes , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.