Blackout risk analysis and control of power system integrated with wind farm

With the increase of wind power penetration, the characteristics of the wind farm have brought a significant impact on the security of power system. It is urgent to study how to reduce the risk of cascading failures while improving the environmental benefits. In this paper, a cascading failure model containing wind farm is proposed, which considers wind power characteristics, such as the structure of wind farm, the randomness of power of wind farm, the virtual inertia control of wind turbine, and the disconnection response of wind turbine after short-circuit faults. In order to identify the key factors of blackout, decision tree is used to analyze results generated from this blackout model. Preventive control is adopted to decrease the probability or effect of critical attributes that can be found in decision tree. The blackout risk of IEEE 30 test system integrated with wind farm is analyzed. Several key factors, such as disconnection of wind turbines from the grid and certain transmission lines, are identified by decision tree. Besides, the effectiveness of the virtual inertial control of wind turbine, reactive power compensation and line construction is verified by simulation.

[1]  Xu Yu-qi Study on equivalent model of wind farms with DIFG considering wake effects , 2014 .

[2]  Bruce H. Krogh,et al.  Wind Integration in Power Systems: Operational Challenges and Possible Solutions , 2011, Proceedings of the IEEE.

[3]  Xiaorong Zhu,et al.  Virtual inertia control of DFIG-based wind turbines for dynamic grid frequency support , 2011 .

[4]  Wang Ta,et al.  Critical Lines Identification of Power Grid Based on the Fault Chain Model , 2014 .

[5]  I. Kamwa,et al.  Causes of the 2003 major grid blackouts in North America and Europe, and recommended means to improve system dynamic performance , 2005, IEEE Transactions on Power Systems.

[6]  Liu Feng,et al.  Identification of key transmission lines in power grid using modified K-core decomposition , 2013, 2013 3rd International Conference on Electric Power and Energy Conversion Systems.

[7]  Li Yong-kai Operational Risk Assessment of Power Grid Cascading Failures Considering Wind Farm Integration , 2013 .

[8]  Wang Ansi Analysis on Serious Wind Turbine Generators Tripping Accident in Northwest China Power Grid in 2011 and Its Lessons , 2012 .

[9]  Wen An An Analysis on Impacts and Characteristics of Stator Voltage of DFIG-based Wind Turbine Generator Under Grid Short Circuit , 2012 .

[10]  M A Matos,et al.  Setting the Operating Reserve Using Probabilistic Wind Power Forecasts , 2011, IEEE Transactions on Power Systems.

[11]  Muhannad S. Bakir,et al.  Tier-independent microfluidic cooling for heterogeneous 3D ICs with nonuniform power dissipation , 2013, 2013 IEEE International Interconnect Technology Conference - IITC.

[12]  Anna Filomena Carbone,et al.  Power Grid Complexity , 2011 .

[13]  G. Tapia,et al.  Modeling and control of a wind turbine driven doubly fed induction generator , 2003 .

[14]  R. Billinton,et al.  Generating capacity adequacy associated with wind energy , 2004, IEEE Transactions on Energy Conversion.