Analysis of human urine protein biomarkers via biomolecular interaction analysis mass spectrometry.

Biomolecular interaction analysis mass spectrometry (BIA/MS) is a two-dimensional chip-based analytical technique geared toward quantitative and qualitative analysis of small volumes of biological samples. Interactions between surface-immobilized ligands and solute-borne analytes are quantitatively viewed in real time through surface plasmon resonance sensing, followed by qualitative matrix-assisted laser desorption/ionization time-of-flight MS analysis of the analyte(s) affinity-retained on the sensor surface. In this work, BIA/MS was used in the detection of a number of protein biomarkers from human urine. Small volumes of human urine were analyzed for cystatin C, beta(2)-microglobulin, urinary protein 1, and retinol-binding protein (RBP). Multiaffinity sensor surfaces were created to simultaneously and rapidly detect all four proteins in a single BIA/MS analysis on a two-flow cell sensor chip configuration. Furthermore, RBP was analyzed separately from both urine and plasma samples. Results indicate that BIA/MS can be used successfully in rapid screening of a number of urinary proteins indicated as putative biological markers for renal dysfunction.

[1]  R. Lauwerys,et al.  Urinary protein 1 or Clara cell protein: a new sensitive marker of proximal tubular dysfunction. , 1994, Kidney international. Supplement.

[2]  M. Newcomer,et al.  The structure of human retinol-binding protein (RBP) with its carrier protein transthyretin reveals an interaction with the carboxy terminus of RBP. , 1999, Biochemistry.

[3]  R. Lauwerys,et al.  Latex immunoassay of retinol-binding protein. , 1982, Clinical chemistry.

[4]  R. Nelson,et al.  Practical considerations in BIA/MS: optimizing the biosensor–mass spectrometry interface , 2000, Journal of molecular recognition : JMR.

[5]  C. Fenselau Peer Reviewed: MALDI MS and Strategies for Protein Analysis , 1997 .

[6]  E C Nice,et al.  Instrumental biosensors: new perspectives for the analysis of biomolecular interactions. , 1999, BioEssays : news and reviews in molecular, cellular and developmental biology.

[7]  S. Loefas,et al.  Immobilization of proteins to a carboxymethyldextran-modified gold surface for biospecific interaction analysis in surface plasmon resonance sensors. , 1991, Analytical biochemistry.

[8]  R. Nelson,et al.  BIA/MS: interfacing biomolecular interaction analysis with mass spectrometry. , 1997, Analytical biochemistry.

[9]  R. Nelson,et al.  Advances in surface plasmon resonance biomolecular interaction analysis mass spectrometry (BIA/MS) , 1999, Journal of molecular recognition : JMR.

[10]  P. A. Peterson,et al.  The complete amino acid sequence of human serum retinol-binding protein. , 1987, Upsala journal of medical sciences.

[11]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[12]  R. Nelson,et al.  Biomolecular Interaction Analysis Mass Spectometry. BIA/MS can detect and characterize protiens in complex biological fluids at the low- to subfemtomole level. , 2000, Analytical chemistry.

[13]  A. Rasooly,et al.  Multitoxin biosensor-mass spectrometry analysis: a new approach for rapid, real-time, sensitive analysis of staphylococcal toxins in food. , 2000, International journal of food microbiology.

[14]  M. Karas,et al.  Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. , 1988, Analytical chemistry.

[15]  M. Piscator Early detection of tubular dysfunction. , 1991, Kidney international. Supplement.

[16]  J. Whicher,et al.  Stability of alpha 1-microglobulin, beta 2-microglobulin and retinol binding protein in urine. , 1989, Clinica chimica acta; international journal of clinical chemistry.

[17]  J. Saurat,et al.  Characterization of two post-translationally processed forms of human serum retinol-binding protein: altered ratios in chronic renal failure. , 1995, Journal of lipid research.

[18]  R. Nelson,et al.  Surface plasmon resonance biomolecular interaction analysis mass spectrometry. 1. Chip-based analysis. , 1997, Analytical chemistry.

[19]  B. Chait,et al.  Matrix-assisted laser-desorption mass spectrometry using 355 nm radiation. , 1989, Rapid communications in mass spectrometry : RCM.

[20]  R. Nelson,et al.  Biosensor chip mass spectrometry: A chip‐based proteomics approach , 2000, Electrophoresis.

[21]  A. Dawnay,et al.  A radioimmunoassay for retinol-binding protein in serum and urine. , 1985, Clinical chemistry.

[22]  J. Stults Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). , 1995, Current opinion in structural biology.

[23]  R. Nelson,et al.  Surface plasmon resonance biomolecular interaction analysis mass spectrometry. 2. Fiber optic-based analysis. , 1997, Analytical chemistry.

[24]  Randall W. Nelson,et al.  Exploring the limit of detection in biomolecular interaction analysis mass spectrometry (BIA/MS): Detection of attomole amounts of native proteins present in complex biological mixtures , 2000 .

[25]  B. Taillon,et al.  BIA/MS of epitope-tagged peptides directly from E. coli lysate: multiplex detection and protein identification at low-femtomole to subfemtomole levels. , 1999, Analytical chemistry.