Optimization on Emergency Longitudinal Ventilation Design

Emergency ventilation design in longitudinally ventilated vehicular tunnels is vital to provide safe egress route for tunnel user under fire situations. In this study, the influences of the location of active fan groups on the upstream velocity are investigated using Computational Fluid Dynamics (CFD) techniques. The numeric model was firstly validated again the experimental data from Memorial Tunnel Fire Ventilation Test Program (MTFVTP). Based on the validated model, parametric studies were then preformed attempting to establish a semi‐empirical correlation between the location of fan groups and the upstream velocity. In the presence of solid fire, it was found that the buoyant force by the fire source and inertial force by the fans interact with each other and resulted in a “leveling‐off” characteristic when the inertial force is no longer dominating. Such interaction re‐distributed the ventilation flow direction and sequentially reduces the magnitude of the upstream velocity. In other word, the indust...