Application of equal area criterion conditions in the time domain for out-of-step protection

A new procedure for out-of-step protection by mapping the equal area criterion conditions to the time domain is proposed in this paper. The classification between stable and out-of-step swings is done using the accelerating and decelerating energies, which represents the area under the power-time curve. The proposed methodology is simple and overcomes some of the difficulties associated with the previous techniques. The proposed approach is based only on the local electrical quantities available at the relay location, and does not depend on the network configuration and parameters. The proposed algorithm has been tested on a single machine infinite bus and a three machine infinite bus system using software simulations. A digital prototype of the relay has also been implemented on the hardware and its performance has been assessed in a closed loop mode using a Real-Time Digital Simulator. The simulation results and the hardware testing results confirm the validity of the approach presented.

[1]  Yutian Liu,et al.  Aspects on Power System Islanding for Preventing Widespread Blackout , 2006, 2006 IEEE International Conference on Networking, Sensing and Control.

[2]  Almoataz Y. Abdelaziz,et al.  Adaptive protection strategies for detecting power system out-of-step conditions using neural networks , 1998 .

[3]  P.W. Sauer,et al.  Stability analysis of power systems by Lyapunov's direct method , 1989, IEEE Control Systems Magazine.

[4]  Virgilio Centeno,et al.  An adaptive out-of-step relay [for power system protection] , 1997 .

[5]  M. Pai Energy function analysis for power system stability , 1989 .

[6]  Waldemar Rebizant,et al.  Fuzzy logic application to out-of-step protection of generators , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[7]  J. Holbach New Out of Step Blocking Algorithm for Detecting Fast Power Swing Frequencies , 2006, 2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources.

[8]  Z.Q. Bo,et al.  An Advanced Real Time Digital Simulator Based Test System for Protection Relays , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[9]  M. A. Pai,et al.  Power system stability : analysis by the direct method of Lyapunov , 1981 .

[10]  Daqing Hou,et al.  Out-of-step protection fundamentals and advancements , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[11]  Shengli Cheng,et al.  Out-of-step protection using the equal area criterion , 2005, Canadian Conference on Electrical and Computer Engineering, 2005..

[12]  C. R. Mason,et al.  The Art and Science of Protective Relaying , 1956 .

[13]  David Thomas,et al.  A new principle for high resistance earth fault detection during fast power swings for distance protection , 1997 .

[14]  R. Kuffel,et al.  Real time digital simulation for control and protection system testing , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[15]  William D. Stevenson,et al.  Elements of Power System Analysis , 1962 .

[16]  K.R. Padiyar,et al.  Online detection of loss of synchronism using energy function criterion , 2006, IEEE Transactions on Power Delivery.