Capacitively Loaded Circularly Polarized Implantable Patch Antenna for ISM Band Biomedical Applications

A single-fed miniaturized circularly polarized microstrip patch antenna is designed and experimentally demonstrated for industrial-scientific-medical (2.4-2.48 GHz) biomedical applications. The proposed antenna is designed by utilizing the capacitive loading on the radiator. Compared with the initial topology of the proposed antenna, the so-called square patch antenna with a center-square slot, the proposed method has the advantage of good size reduction and good polarization purity. The footprint of the proposed antenna is 10×10×1.27 mm3. The simulated impedance, axial ratio, and radiation pattern are studied and compared in two simulation models: cubic skin phantom and Gustav voxel human body. The effect of different body phantoms is discussed to evaluate the sensitivity of the proposed antenna. The effect of coaxial cable is also discussed. Two typical approaches to address the biocompatibility issue for practical applications are reported as well. The simulated and measured impedance bandwidths in cubic skin phantom are 7.7% and 10.2%, respectively. The performance of the communication link between the implanted CP antenna and the external antenna is also presented.

[1]  Tutku Karacolak,et al.  In Vivo Verification of Implantable Antennas Using Rats as Model Animals , 2010, IEEE Antennas and Wireless Propagation Letters.

[2]  Michael J. Lancaster,et al.  Capacitively loaded microstrip loop resonator , 1994 .

[3]  Y. Rahmat-Samii,et al.  Implanted antennas inside a human body: simulations, designs, and characterizations , 2004, IEEE Transactions on Microwave Theory and Techniques.

[4]  Wen‐Shyang Chen,et al.  Novel compact circularly polarized square microstrip antenna , 2001 .

[5]  Chao-Ming Wu,et al.  Bandwidth enhancement and size reduction of an implantable PIFA antenna for biotelemetry devices , 2009 .

[6]  Masaharu Takahashi,et al.  A helical folded dipole antenna for implantable communication devices , 2010, 2010 IEEE Antennas and Propagation Society International Symposium.

[7]  Peng Liu,et al.  22-pJ/bit Energy-Efficient 2.4-GHz Implantable OOK Transmitter for Wireless Biotelemetry Systems: In Vitro Experiments Using Rat Skin-Mimic , 2010, IEEE Transactions on Microwave Theory and Techniques.

[8]  J. Row,et al.  Compact design of single-feed circularly polarised microstrip antenna , 2004 .

[9]  Kwai-Man Luk,et al.  Small Circularly Polarized U-Slot Wideband Patch Antenna , 2011, IEEE Antennas and Wireless Propagation Letters.

[10]  Kin-Lu Wong,et al.  Circularly polarised microstrip antenna with a tuning stub , 1998 .

[11]  M. Samet,et al.  Parametric study on the dielectric properties of biological tissues , 2015, 2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA).

[12]  Minkyu Je,et al.  Differentially Fed Dual-Band Implantable Antenna for Biomedical Applications , 2012, IEEE Transactions on Antennas and Propagation.

[13]  Oscar Quevedo-Teruel,et al.  Dual-band microstrip patch antenna based on short-circuited ring and spiral resonators for implantable medical devices , 2010 .

[14]  M. Takahashi,et al.  Performances of an Implanted Cavity Slot Antenna Embedded in the Human Arm , 2009, IEEE Transactions on Antennas and Propagation.

[15]  A. K. Skrivervik,et al.  Design, Realization and Measurements of a Miniature Antenna for Implantable Wireless Communication Systems , 2011, IEEE Transactions on Antennas and Propagation.

[16]  T. Itoh,et al.  Compact Circularly-Polarized Patch Antenna Loaded With Metamaterial Structures , 2011, IEEE Transactions on Antennas and Propagation.

[17]  E. Topsakal,et al.  Design of a Dual-Band Implantable Antenna and Development of Skin Mimicking Gels for Continuous Glucose Monitoring , 2008, IEEE Transactions on Microwave Theory and Techniques.

[18]  Shaoqiu Xiao,et al.  Compact Dual-Band Antenna for Implantable Devices , 2012, IEEE Antennas and Wireless Propagation Letters.

[19]  Chien-Ming Lee,et al.  Dual-resonant π-shape with double L-strips PIFA for implantable biotelemetry , 2008 .

[20]  B. Fuchs,et al.  The Effect of Insulating Layers on the Performance of Implanted Antennas , 2011, IEEE Transactions on Antennas and Propagation.

[21]  Li-Jie Xu,et al.  Dual-Band Implantable Antenna With Open-End Slots on Ground , 2012, IEEE Antennas and Wireless Propagation Letters.

[22]  K. Sarabandi,et al.  Low Profile, Miniaturized, Inductively Coupled Capacitively Loaded Monopole Antenna , 2012, IEEE Transactions on Antennas and Propagation.

[23]  Quan Xue,et al.  Virtually Shorted Patch Antenna for Circular Polarization , 2010, IEEE Antennas and Wireless Propagation Letters.

[24]  E. Topsakal,et al.  Characterization and Testing of a Skin Mimicking Material for Implantable Antennas Operating at ISM Band (2.4 GHz-2.48 GHz) , 2008, IEEE Antennas and Wireless Propagation Letters.

[25]  M. Ammann,et al.  Dual-Frequency Circularly-Polarized Patch Antenna With Compact Size and Small Frequency Ratio , 2007, IEEE Transactions on Antennas and Propagation.

[26]  H. Iwasaki A circularly polarized small-size microstrip antenna with a cross slot , 1996 .

[27]  Y. Rahmat-Samii,et al.  Conformal Ingestible Capsule Antenna: A Novel Chandelier Meandered Design , 2009, IEEE Transactions on Antennas and Propagation.

[28]  C.M. Furse,et al.  Design of implantable microstrip antenna for communication with medical implants , 2004, IEEE Transactions on Microwave Theory and Techniques.

[29]  K. Sarabandi,et al.  A Topology-Based Miniaturization of Circularly Polarized Patch Antennas , 2013, IEEE Transactions on Antennas and Propagation.

[30]  H. Yoo,et al.  A Planar MICS Band Antenna Combined With a Body Channel Communication Electrode for Body Sensor Network , 2009, IEEE Transactions on Microwave Theory and Techniques.

[31]  Nasimuddin,et al.  Compact Asymmetric-Slit Microstrip Antennas for Circular Polarization , 2011, IEEE Transactions on Antennas and Propagation.

[32]  Chien-Min Cheng,et al.  Development of Nonsuperstrate Implantable Low-Profile CPW-Fed Ceramic Antennas , 2010, IEEE Antennas and Wireless Propagation Letters.

[33]  John C. Batchelor,et al.  Antennas and Propagation for Body-Centric Wireless Communications , 2012 .

[34]  Quan Xue,et al.  Design of Small Circularly Polarized Patch Antenna , 2010, IEEE Antennas and Wireless Propagation Letters.

[35]  A. Kiourti,et al.  A Review of Implantable Patch Antennas for Biomedical Telemetry: Challenges and Solutions [Wireless Corner] , 2012, IEEE Antennas and Propagation Magazine.

[36]  A. Kiourti,et al.  Miniature Scalp-Implantable Antennas for Telemetry in the MICS and ISM Bands: Design, Safety Considerations and Link Budget Analysis , 2012, IEEE Transactions on Antennas and Propagation.

[37]  U. Kawoos,et al.  Characterization of Implantable Antennas for Intracranial Pressure Monitoring: Reflection by and Transmission Through a Scalp Phantom , 2008, IEEE Transactions on Microwave Theory and Techniques.

[38]  Yong-xin Guo,et al.  Compact circularly-polarised microstrip antenna with symmetric-slit , 2012 .

[39]  Michael Elsdon,et al.  Compact circular polarised patch antenna with relaxed manufacturing tolerance and improved axial ratio bandwidth , 2003 .

[40]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[41]  H.-D. Chen Compact circularly polarised microstrip antenna with slotted ground plane , 2002 .

[42]  Hua-Ming Chen,et al.  On the circular polarization operation of annular-ring microstrip antennas , 1999 .

[43]  G. Lazzi,et al.  Impedance matching and implementation of planar space-filling dipoles as intraocular implanted antennas in a retinal prosthesis , 2005, IEEE Transactions on Antennas and Propagation.

[44]  Zhi Ning Chen,et al.  Transmission of RF Signals Between MICS Loop Antennas in Free Space and Implanted in the Human Head , 2009, IEEE Transactions on Antennas and Propagation.