Portable, low-cost NMR with laser-lathe lithography produced microcoils.

Nuclear Magnetic Resonance (NMR) is unsurpassed in its ability to non-destructively probe chemical identity. Portable, low-cost NMR sensors would enable on-site identification of potentially hazardous substances, as well as the study of samples in a variety of industrial applications. Recent developments in RF microcoil construction (i.e. coils much smaller than the standard 5mm NMR RF coils), have dramatically increased NMR sensitivity and decreased the limits-of-detection (LOD). We are using advances in laser pantographic microfabrication techniques, unique to LLNL, to produce RF microcoils for field deployable, high sensitivity NMR-based detectors. This same fabrication technique can be used to produce imaging coils for MRI as well as for standard hardware shimming or "ex-situ" shimming of field inhomogeneities typically associated with inexpensive magnets. This paper describes a portable NMR system based on the use of a 2 kg hand-held permanent magnet, laser-fabricated microcoils, and a compact spectrometer. The main limitations for such a system are the low resolution and sensitivity associated with the low field values and quality of small permanent magnets, as well as the lack of large amounts of sample of interest in most cases. The focus of the paper is on the setting up of this system, initial results, sensitivity measurements, discussion of the limitations and future plans. The results, even though preliminary, are promising and provide the foundation for developing a portable, inexpensive NMR system for chemical analysis. Such a system will be ideal for chemical identification of trace substances on site.

[1]  A. Webb,et al.  RF microcoil design for practical NMR of mass-limited samples. , 1998, Journal of magnetic resonance.

[2]  B Blümich,et al.  Velocity imaging by ex situ NMR. , 2005, Journal of magnetic resonance.

[3]  Bernhard Blümich,et al.  Ex Situ NMR in Highly Homogeneous Fields: 1H Spectroscopy , 2007, Science.

[4]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[5]  Hans-Peter Raich,et al.  Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas , 2004 .

[6]  A. Pines,et al.  Approach to High-Resolution ex Situ NMR Spectroscopy , 2001, Science.

[7]  Jonathan V. Sweedler,et al.  High-Resolution NMR Spectroscopy of Sample Volumes from 1 nL to 10 μL , 1999 .

[8]  B. Blümich,et al.  Soft‐matter analysis by the NMR‐MOUSE , 2000 .

[9]  Hailu,et al.  Nuclear magnetic resonance in inhomogeneous magnetic fields , 2000, Journal of magnetic resonance.

[10]  George M. Whitesides,et al.  Constructing single- and multiple-helical microcoils and characterizing their performance as components of microinductors and microelectromagnets , 1997 .

[11]  R. Fechete,et al.  Selective NMR excitation in strongly inhomogeneous magnetic fields. , 2003, Journal of magnetic resonance.

[12]  A. Webb,et al.  On-line NMR detection of amino acids and peptides in microbore LC. , 1995, Analytical chemistry.

[13]  S Sharma,et al.  Degradation of historical paper: nondestructive analysis by the NMR-MOUSE. , 2003, Journal of magnetic resonance.

[14]  R. Ehrlich,et al.  Pore-Size Distribution And NMR In Microporous Cherty Sandstones , 1989 .

[15]  A. Webb,et al.  Design of solenoidal microcoils for high-resolution 13C NMR spectroscopy. , 1998, Analytical chemistry.

[16]  Daniel Topgaard,et al.  "Shim pulses" for NMR spectroscopy and imaging. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Stray field magnetic resonance imaging , 1998 .

[18]  B Blümich,et al.  One-dimensional imaging with a palm-size probe. , 2000, Journal of magnetic resonance.

[19]  B. Blümich,et al.  A Mobile NMR Device for Measurements of Porosity and Pore Size Distributions of Drilled Core Samples , 2004 .

[20]  Bernhard Blümich,et al.  The NMR MOUSE, a Mobile Universal Surface Explorer , 1996 .

[21]  P C Lauterbur,et al.  Design and analysis of microcoils for NMR microscopy. , 1995, Journal of magnetic resonance. Series B.

[22]  Charles Pennington,et al.  Triaxial magnetic field gradient system for microcoil magnetic resonance imaging , 2000 .

[23]  The NMR-MOUSE: quality control of elastomers. , 2001, Magnetic resonance imaging.

[24]  Kevin R. Minard,et al.  Solenoidal microcoil design—part II: optimizing winding parameters for maximum signal-to-noise performance , 2001 .

[25]  Eiichi Fukushima,et al.  Experimental pulse NMR : a nuts and bolts approach , 2018 .

[26]  Richard L. Magin,et al.  Miniature permanent magnet for table‐top NMR , 2003 .

[27]  M. V. Shutov,et al.  Development of low field nuclear magnetic resonance microcoils , 2005 .

[28]  B. Blümich,et al.  Two-dimensional imaging with a single-sided NMR probe. , 2003, Journal of magnetic resonance.

[29]  D. Murphy Advances in MWD and formation evaluation for 2004 , 2003 .

[30]  D. P. Murphy Advances in MWD and formation evaluation for 1997 , 1995 .

[31]  G. Whitesides,et al.  Using microcontact printing to fabricate microcoils on capillaries for high resolution proton nuclear magnetic resonance on nanoliter volumes , 1997 .

[32]  B. Blümich,et al.  Characterization of cross-link density in technical elastomers by the NMR-MOUSE. , 1998, Solid state nuclear magnetic resonance.

[33]  B. Blümich,et al.  Anisotropy in tendon investigated in vivo by a portable NMR scanner, the NMR-MOUSE. , 2000, Journal of magnetic resonance.

[34]  V. Demas,et al.  Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design , 2008, IEEE Transactions on Magnetics.

[35]  H. T. Pedersen,et al.  Application of the NMR-MOUSE to food emulsions. , 2003, Journal of magnetic resonance (San Diego, Calif. 1997 : Print).

[36]  Robert L. Kleinberg,et al.  NMR well logging at Schlumberger , 2001 .

[37]  V. Malba,et al.  Magnetic susceptibility measurements at high pressure using designer diamond anvils , 2003 .

[38]  J. Perlo,et al.  High-Resolution NMR Spectroscopy with a Portable Single-Sided Sensor , 2005, Science.

[39]  Vincent Malba,et al.  Laser-Lathe Lithography—a Novel Method for Manufacturing Nuclear Magnetic Resonance Microcoils , 2003 .

[40]  P. Callaghan Principles of Nuclear Magnetic Resonance Microscopy , 1991 .

[41]  Stray Field Imaging by Magnetic Field Sweep , 1998 .

[42]  D Capitani,et al.  Monitoring degradation in paper: non-invasive analysis by unilateral NMR. Part II. , 2004, Journal of magnetic resonance.

[43]  Robin Dykstra,et al.  A nuclear magnetic resonance study of Antarctic sea ice brine diffusivity , 1999 .

[44]  Rita E Serda,et al.  1H NMR Detection of superparamagnetic nanoparticles at 1T using a microcoil and novel tuning circuit. , 2006, Journal of magnetic resonance.

[45]  Richard L. Magin,et al.  High-Resolution Microcoil 1H-NMR for Mass-Limited, Nanoliter-Volume Samples , 1995, Science.

[46]  Jonathan V. Sweedler,et al.  High‐Resolution NMR Spectroscopy of Sample Volumes from 1 nL to 10 μL , 1999 .

[47]  Kevin R. Minard,et al.  Solonoidal microcoil design: optimizing RF homogeneity and coil dimensions , 2001 .

[48]  Bruce J Balcom,et al.  A constant gradient unilateral magnet for near-surface MRI profiling. , 2006, Journal of magnetic resonance.

[49]  B. Blümich,et al.  Analysis of polymer materials by surface NMR via the MOUSE. , 1998, Journal of magnetic resonance.

[50]  Mobile NMR: Applications to materials and biomedicine , 2006 .

[51]  Klaus Halbach,et al.  Physical and optical properties of rare earth cobalt magnets , 1980 .

[52]  Andrew G. Webb,et al.  Radiofrequency microcoils in magnetic resonance , 1997 .

[53]  B Blümich,et al.  Velocity distributions remotely measured with a single-sided NMR sensor. , 2004, Journal of magnetic resonance.