Flow and contaminant transport in an airliner cabin induced by a moving body: Model experiments and CFD predictions

The effects of a moving human body on flow and contaminant transport inside an aircraft cabin were investigated. Experiments were performed in a one-tenth scale, water-based model. The flow field and contaminant transport were measured using the Particle Image Velocimetry (PIV) and Planar Laser-Induced Fluorescence (PLIF) techniques, respectively. Measurements were obtained with (ventilation case) and without (baseline case) the cabin environmental control system (ECS). The PIV measurements show strong intermittency in the instantaneous near-wake flow. A symmetric downwash flow was observed along the vertical centerline of the moving body in the baseline case. The evolution of this flow pattern is profoundly perturbed by the flow from the ECS. Furthermore, a contaminant originating from the moving body is observed to convect to higher vertical locations in the presence of ventilation. These experimental data were used to validate a Computational Fluid Dynamic (CFD) model. The CFD model can effectively capture the characteristic flow features and contaminant transport observed in the small-scale model.

[1]  Frank Thiele,et al.  Comparison of LES and RANS in bluff-body flows , 2001 .

[2]  H Brohus,et al.  Influence of movements on contaminant transport in an operating room. , 2006, Indoor air.

[3]  Qingyan Chen,et al.  A Procedure for Verification, Validation, and Reporting of Indoor Environment CFD Analyses , 2002 .

[4]  Zhiqiang John Zhai,et al.  Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature , 2007 .

[5]  A J Gadgil,et al.  Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow. , 2004, Indoor air.

[6]  Zhiqiang Zhai,et al.  Design of a Ventilation System for an Indoor Auto Racing Complex , 2002 .

[7]  Kow-Tong Chen,et al.  Transmission of the severe acute respiratory syndrome on aircraft. , 2003, The New England journal of medicine.

[8]  Matthias Kühn,et al.  Experimental parametric study of forced and mixed convection in a passenger aircraft cabin mock-up , 2009 .

[9]  D. Musher How contagious are common respiratory tract infections? , 2003, The New England journal of medicine.

[10]  J. Edwards,et al.  Large eddy simulation and zonal modeling of human-induced contaminant transport. , 2008, Indoor air.

[11]  Charles DeJohn,et al.  Responding to medical events during commercial airline flights. , 2002, The New England journal of medicine.

[12]  Hiroshi Matsumoto,et al.  The Influence of a Moving Object on Air Distribution in Displacement Ventilated Rooms , 2004 .

[13]  Tayfun E. Tezduyar,et al.  Finite Element Methods for Fluid Dynamics with Moving Boundaries and Interfaces , 2004 .

[14]  K. Castro,et al.  Transmission of multidrug-resistant Mycobacterium tuberculosis during a long airplane flight. , 1996, The New England journal of medicine.

[15]  P. Quinlisk,et al.  Update: multistate outbreak of mumps--United States, January 1-May 2, 2006. , 2006, MMWR. Morbidity and mortality weekly report.

[16]  S. Lele,et al.  Motion of particles with inertia in a compressible free shear layer , 1991 .

[17]  Qingyan Chen,et al.  Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft. , 2008, Journal of environmental monitoring : JEM.

[18]  Magnus Mattsson,et al.  Displacement Ventilation: effects of movement and exhalation , 1997 .

[19]  K H Dunn,et al.  Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. 1. Numerical simulation of the flow field. , 2005 .

[20]  Yigang Sun,et al.  Experimental characterization of airflows in aircraft cabins, Part II: Results and research recommendations. Discussion , 2005 .

[21]  S Settles,et al.  FLUID MECHANICS AND HOMELAND SECURITY , 2006 .

[22]  Stephane B. Poussou,et al.  Experimental investigation of airborne contaminant transport by a human wake moving in a ventilated aircraft cabin , 2008 .

[23]  P V Nielsen,et al.  Dispersal of exhaled air and personal exposure in displacement ventilated rooms. , 2002, Indoor air.

[24]  R G Sextro,et al.  Pollutant dispersion in a large indoor space: Part 1 -- Scaled experiments using a water-filled model with occupants and furniture. , 2004, Indoor air.

[25]  Markus Raffel,et al.  Particle Image Velocimetry: A Practical Guide , 2002 .

[26]  Paul Linden,et al.  Buoyancy-driven ventilation between two chambers , 2002, Journal of Fluid Mechanics.

[27]  A. Danchin,et al.  The Severe Acute Respiratory Syndrome , 2003 .

[28]  Thomas J. R. Hughes,et al.  Encyclopedia of computational mechanics , 2004 .

[29]  Yang-Cheng Shih,et al.  Dynamic airflow simulation within an isolation room , 2006, Building and Environment.

[30]  M. Osterholm,et al.  Exposure to Mycobacterium tuberculosis during air travel , 1993, The Lancet.

[31]  Peter Freymuth,et al.  Flow visualization in fluid mechanics , 1993 .

[32]  Zhao Zhang,et al.  Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup , 2009 .