A blood-assisted optical biosensor for automatic glucose determination.

A new approach for glucose determination in blood based on the spectroscopic properties of blood hemoglobin (Hb) is presented. The biosensor consists of a glucose oxidase (GOx) entrapped polyacrylamide (PAA) film placed in a flow cell. Blood is simply diluted with bidistilled water (150:1, v:v) and injected into the carrier solution. When reaching the PAA film, the blood glucose reacts with the GOx and the resulting H(2)O(2) reacts with the blood Hb. This produces an absorbance change in this compound. The GOx-PAA film can be used at least 100 times. Lateral reactions of H(2)O(2) with other blood constituents are easily blocked (by azide addition). The linear response range can be fitted between 20 and 1200 mg dL(-1) glucose (R.S.D. 4%, 77 mg dL(-1)). In addition to the use of untreated blood, two important analytical aspects of the method are: (1) the analyte concentration can be obtained by an absolute calibration method; and (2) the signal is not dependent on the oxygen concentration. A mathematical model relating the Hb absorbance variation during the reaction with the glucose concentration has been developed to provide theoretical support and to predict its application to other compounds after changing the GOx by another enzyme. The method has been applied to direct glucose determination in 10 blood samples, and a correlation coefficient higher than 0.98 was obtained after comparing the results with those determined by an automatic analyzer. As well as sharing some of the advantages of disposable amperometric biosensors, the most significant feature of this approach is its reversibility.

[1]  A. Cass,et al.  Fluorescent peptide probes for high-throughput measurement of protein phosphatases. , 2003, Analytical chemistry.

[2]  M. Arnold,et al.  Enzymatically prepared poly(hydroquinone) as a mediator for amperometric glucose sensors , 1998 .

[3]  W. Tamborlane,et al.  Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes. , 2001, Diabetes care.

[4]  V. Sanz,et al.  Uric acid determination using uricase and the autotransducer molecular absorption properties of peroxidase. , 2008, Analytica chimica acta.

[5]  L. Martens,et al.  Review: The physiology of saliva and transfer of drugs into saliva. , 2005, Forensic science international.

[6]  S. Asher,et al.  Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. , 2004, Clinical chemistry.

[7]  R. Hoess,et al.  Protein design and phage display. , 2001, Chemical reviews.

[8]  G. S. Wilson,et al.  Biosensors for real-time in vivo measurements. , 2005, Biosensors & bioelectronics.

[9]  J. Ubbink,et al.  Analytical quality of near-patient blood cholesterol and glucose determinations. , 2000, Clinical chemistry.

[10]  V. Sanz,et al.  A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase. , 2007, Biosensors & bioelectronics.

[11]  N. Evans,et al.  Fluorescence-based glucose sensors. , 2005, Biosensors & bioelectronics.

[12]  Sverre Sandberg,et al.  Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation. , 2005, Clinical chemistry.

[13]  N. Evans,et al.  In vivo glucose monitoring: the clinical reality and the promise. , 2005, Biosensors & bioelectronics.

[14]  Viviana Scognamiglio,et al.  Protein-Based Biosensors for Diabetic Patients , 2004, Journal of Fluorescence.

[15]  Homme W Hellinga,et al.  Local encoding of computationally designed enzyme activity. , 2007, Journal of molecular biology.

[16]  R O Potts,et al.  Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes. , 2001, Biosensors & bioelectronics.

[17]  Gopal Das,et al.  Substrate-independent transduction of chromophore-free organic and biomolecular transformations into color. , 2006, Chemistry.

[18]  Using blood hemoglobin for blood analysis. , 2007, The Analyst.

[19]  V. Sanz,et al.  Direct glucose determination in blood using a reagentless optical biosensor. , 2007, Biosensors & bioelectronics.

[20]  S. Daunert,et al.  Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor , 2004, Journal of Fluorescence.

[21]  S. Ballas,et al.  Aggregation of normal and sickle hemoglobin in high concentration phosphate buffer. , 2004, Biophysical journal.

[22]  J. Castillo,et al.  Intrinsic fluorescence of enzymes and fluorescence of chemically modified enzymes for analytical purposes: a review. , 2001, Luminescence : the journal of biological and chemical luminescence.

[23]  M. Karp,et al.  Reporter genes lucFF, luxCDABE, gfp, and dsred have different characteristics in whole-cell bacterial sensors. , 2002, Analytical biochemistry.

[24]  T. Brittain The ferric form of the three human embryonic hemoglobins and their reactions with azide ions. , 2000, Journal of inorganic biochemistry.