Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences

PurposeTo compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI).Materials and methodsTwenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 × 0.5 × 3 mm3; ∼10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm3; ∼7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm3; ∼5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared.ResultsMSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001).ConclusionsThe CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci.

[1]  Richard Kijowski,et al.  Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging--diagnostic performance compared with that of conventional MR imaging at 3.0 T. , 2009, Radiology.

[2]  Richard Kijowski,et al.  Cartilage morphology at 3.0T: Assessment of three‐dimensional magnetic resonance imaging techniques , 2010, Journal of magnetic resonance imaging : JMRI.

[3]  Sebastian Kozerke,et al.  MRI temporal acceleration techniques , 2012, Journal of magnetic resonance imaging : JMRI.

[4]  Michaela Schmidt,et al.  Highly undersampled contrast‐enhanced MRA with iterative reconstruction: Integration in a clinical setting , 2015, Magnetic resonance in medicine.

[5]  Kenneth S. Lee,et al.  Rapid isotropic resolution cartilage assessment using radial alternating repetition time balanced steady‐state free‐precession imaging , 2014, Journal of magnetic resonance imaging : JMRI.

[6]  David Moratal,et al.  “PINOT”: Time‐resolved parallel magnetic resonance imaging with a reduced dynamic field of view , 2011, Magnetic resonance in medicine.

[7]  Jeffrey Tsao,et al.  Ultrafast imaging: Principles, pitfalls, solutions, and applications , 2010, Journal of magnetic resonance imaging : JMRI.

[8]  Philip J Beatty,et al.  Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. , 2007, AJR. American journal of roentgenology.

[9]  Richard Kijowski,et al.  Routine 3D magnetic resonance imaging of joints , 2011, Journal of magnetic resonance imaging : JMRI.

[10]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[11]  Young Cheol Yoon,et al.  Knee derangements: comparison of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging. , 2013, Radiology.

[12]  Thomas M. Link,et al.  Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance , 2009, European Radiology.

[13]  Guobin Li,et al.  Improving the robustness of 3D turbo spin echo imaging to involuntary motion , 2015, Magnetic Resonance Materials in Physics, Biology and Medicine.

[14]  Nancy A Obuchowski,et al.  MRI of the knee ligaments and menisci: comparison of isotropic-resolution 3D and conventional 2D fast spin-echo sequences at 3 T. , 2011, AJR. American journal of roentgenology.

[15]  Richard Kijowski,et al.  Evaluation of the Articular Cartilage of the Knee Joint Using an Isotropic Resolution 3D Fast Spin-Echo Sequence With Conventional and Radial Reformatted Images. , 2015, AJR. American journal of roentgenology.

[16]  Leon Axel,et al.  Combination of Compressed Sensing and Parallel Imaging for Highly-Accelerated 3 D First-Pass Cardiac Perfusion MRI , 2009 .

[17]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[18]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[19]  Brian A Hargreaves,et al.  Driven equilibrium magnetic resonance imaging of articular cartilage: Initial clinical experience , 2005, Journal of magnetic resonance imaging : JMRI.

[20]  S. Herman,et al.  Partial tears of the anterior cruciate ligament: diagnostic performance of isotropic three-dimensional fast spin echo (3D-FSE-Cube) MRI , 2012, European Journal of Orthopaedic Surgery & Traumatology.

[21]  A. Naraghi,et al.  Three-dimensional MRI of the musculoskeletal system. , 2012, AJR. American journal of roentgenology.

[22]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[23]  P. Parizel,et al.  Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T , 2012, Insights into Imaging.

[24]  S. Reeder,et al.  Clinical usefulness of adding 3D cartilage imaging sequences to a routine knee MR protocol. , 2011, AJR. American journal of roentgenology.

[25]  D. Thomasson,et al.  Isotropic 3D fast spin-echo with proton-density-like contrast: a comprehensive approach to musculoskeletal MRI. , 2007, AJR. American journal of roentgenology.

[26]  Richard Kijowski,et al.  Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation , 2012, Skeletal Radiology.

[27]  Jong Chul Ye,et al.  k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI , 2009, Magnetic resonance in medicine.

[28]  Jin Hwan Ahn,et al.  Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences. , 2009, Radiology.