High-Quality Tissue Imaging Using a Catheter-Based Swept-Source Optical Coherence Tomography Systems With an Integrated Semiconductor Optical Amplifier

We present the analysis and characteristics of an optical fiber catheter-based swept-source optical coherence tomography (SS-OCT) system for tissue imaging. A quadrature Mach-Zehnder interferometer based on multiport fiber couplers and a semiconductor optical amplifier were employed in our SS-OCT system in order to increase the signal-to-noise ratio, therefore improving image quality deeper within the tissue. We demonstrate OCT images of human skin and arterial tissue acquired with our OCT engine. The results show that this OCT system is an effective imaging modality for real-time diagnosis and in vivo biological applications.

[1]  Youxin Mao,et al.  Analyses and calculations of noise in optical coherence tomography systems , 2008 .

[2]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[3]  Shoude Chang,et al.  Design and implementation of fiber lenses for ultra-small probes used in biomedical imaging , 2007, SPIE/COS Photonics Asia.

[4]  Shoude Chang,et al.  3x3 Mach-Zehnder interferometer with unbalanced differential detection for full-range swept-source optical coherence tomography. , 2008, Applied optics.

[5]  Qiang Wang,et al.  Investigation of coherent amplification with a semiconductor optical amplifier employed in a swept source OCT system , 2007, SPIE BiOS.

[6]  Kota Asaka,et al.  Improved Sensitivity of Optical Frequency Domain Reflectometry-Optical Coherence Tomography Using a Semiconductor Optical Amplifier , 2006 .

[7]  N. Weissman,et al.  Plaque characterization with optical coherence tomography. , 2006, Journal of the American College of Cardiology.

[8]  Jianglin Fan,et al.  Development of an animal model for spontaneous myocardial infarction (WHHLMI rabbit). , 2003, Arteriosclerosis, thrombosis, and vascular biology.

[9]  Changhuei Yang,et al.  Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers. , 2005, Optics express.

[10]  Lars Thrane,et al.  Diagnostic potential of optical coherence tomography in non-melanoma skin cancer: a clinical study , 2007, European Conference on Biomedical Optics.

[11]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[12]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[13]  Terence A. King,et al.  Theoretical comparison of light sources for use in optical coherence tomography , 2002, SPIE BiOS.

[14]  M. Sowa,et al.  Imaging of biomedical turbid tissue using catheter swept-source optical coherence tomography , 2010, 2010 IEEE International Workshop on Medical Measurements and Applications.

[15]  Jianglin Fan,et al.  Development of an Animal Model for Spontaneous Myocardial Infarction (WHHLMI Rabbit) , 2003 .

[16]  J. Izatt,et al.  Optimal interferometer designs for optical coherence tomography. , 1999, Optics letters.

[17]  A. Podoleanu,et al.  Limitation of the achievable signal-to-noise ratio in optical coherence tomography due to mismatch of the balanced receiver. , 2004, Applied optics.

[18]  K. Seung,et al.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. , 2002, Journal of the American College of Cardiology.

[19]  S. Yun,et al.  High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter. , 2003, Optics letters.

[20]  Jennifer K. Barton,et al.  Using Optical coherence tomography as an aid in chemoprevention of skin cancer , 2005 .

[21]  Victor X D Yang,et al.  Interstitial Doppler optical coherence tomography. , 2005, Optics letters.

[22]  Joseph M Schmitt,et al.  Current and future developments in intracoronary optical coherence tomography imaging. , 2009, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[23]  J. Fujimoto,et al.  Imaging needle for optical coherence tomography. , 2000, Optics letters.

[24]  A. Podoleanu Unbalanced versus balanced operation in an optical coherence tomography system. , 2000, Applied optics.