Multi-turn time-of-flight mass spectrometers with electrostatic sectors.

The mass resolution of a time-of-flight (TOF) mass spectrometer is directly proportional to its total flight pathlength. Multi-turn or multi-passage ion optical geometries are necessary to obtain fight distances of sufficient length within reasonable size limitations. We have investigated ion optics for a multi-turn TOF mass spectrometer with electrostatic sectors. The concept of 'perfect' focusing conditions is introduced. Furthermore, a new type of multi-turn TOF mass spectrometer, the MULTUM Linear plus, was developed. It consists of four cylindrical electric sectors and 28 electric quadrupole lenses. It has a vacuum chamber 60 x 70 x 20 cm in size. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of 350 000 (m/z = 28, FWHM) was achieved after 501.5 cycles. The MULTUM Linear plus analyzer is not simple, however; 28 electric quadrupole lenses are used. In order to reduce the number of ion optical parts, an improved multi-turn TOF mass spectrometer, the MULTUM II, consisting of only four toroidal electric sectors, was also developed. The possibility of tandem mass spectrometric applications using multi-turn TOF mass spectrometers is also discussed.

[1]  H. Nakabushi,et al.  Flight time of relativistically fast particles in crossed toroidal electric and inhomogeneous magnetic fields , 1983 .

[2]  Hermann Wollnik,et al.  Time-of-flight mass spectrometers with multiply reflected ion trajectories , 1990 .

[3]  I. Katakuse,et al.  A Simple Multi-Turn Time of Flight Mass Spectrometer ‘MULTUM II’ , 2003 .

[4]  T. Sakurai,et al.  A new time-of-flight mass spectrometer , 1985 .

[5]  M. Guilhaus,et al.  Orthogonal acceleration time-of-flight mass spectrometry. , 2000, Mass spectrometry reviews.

[6]  T. Matsuo,et al.  A Space Time-of-Flight Mass Spectrometer for Exobiologically-Oriented Applications , 1999 .

[7]  A. Kholomeev,et al.  Multipass time-of-flight mass spectrometers with high resolving powers , 2001 .

[8]  H. Rosenbauer,et al.  Construction of a new multi-turn time-of-flight mass spectrometer. , 2000, Journal of mass spectrometry : JMS.

[9]  T. Matsuo,et al.  The electrostatic potential in a toroidal condenser , 1972 .

[10]  H. Matsuda,et al.  Potential distribution in a cylindrical condenser terminated by Matsuda plates , 1975 .

[11]  R. Cooks,et al.  A tandem time-of-flight mass spectrometer for surface-induced dissociation , 1987 .

[12]  W. Poschenrieder Multiple-focusing time-of-flight mass spectrometers Part II. TOFMS with equal energy acceleration , 1971 .

[13]  T. Matsuo,et al.  Computer program “TRIO-DRAW” for displaying ion trajectory and flight time , 1999 .

[14]  Ronald C. Beavis,et al.  Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers. , 1991, Analytical chemistry.

[15]  I. Mclaren,et al.  TIME-OF-FLIGHT MASS SPECTROMETER WITH IMPROVED RESOLUTION , 1955 .

[16]  T. Hiasa,et al.  A new multi-passage time-of-flight mass spectrometer at JAIST , 1999 .

[17]  T. Matsuo,et al.  Perfect space and time focusing ion optics for multiturn time of flight mass spectrometers , 2000 .

[18]  T. Matsuo,et al.  Ion optics for time-of-flight mass spectrometers with multiple symmetry , 1985 .

[19]  H. Wollnik,et al.  An energy-isochronous multi-pass time-of-flight mass spectrometer consisting of two coaxial electrostatic mirrors , 2003 .

[20]  T. Matsuo,et al.  Ion optics for multi-turn time-of-flight mass spectrometers with variable mass resolution , 1997 .

[21]  J. Henion,et al.  Structural characterization of protein tryptic peptides via liquid chromatography/mass spectrometry and collision-induced dissociation of their doubly charged molecular ions. , 1991, Analytical chemistry.