Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane.

A procedure is described that provides co-immobilization of enzyme and bovine serum albumin (BSA) within an alumina sol-gel matrix and a polyphenol layer permselective for endogenous electroactive species. BSA has first been employed for the immobilization of glucose oxidase (GOx) on a Pt electrode in a sol-gel to produce a uniform, thin and compact film with enhanced enzyme activity. Electropolymerization of phenol was then employed to form an anti-interference and protective polyphenol film within the enzyme layer. In addition, a stability-reinforcing membrane derived from (3-aminopropyl)-trimethoxysilane was constructed by electrochemically-assisted crosslinking. This hybrid film outside the enzyme layer contributed both to the improved stability and to permselectivity. The resulting glucose sensor was characterized by a short response time (<10 s), high sensitivity (10.4 nA/mM mm(2)), low interference from endogenous electroactive species, and a working lifetime of at least 60 days.

[1]  D. Pfeiffer Commercial biosensors for medical application. , 1997, EXS.

[2]  Alexander M. Yacynych,et al.  Electropolymerized films to prevent interferences and electrode fouling in biosensors , 1991 .

[3]  Soichi Yabuki,et al.  Glucose oxidase/polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensor , 1998 .

[4]  David Avnir,et al.  Biochemically active sol-gel glasses: The trapping of enzymes ☆ , 1990 .

[5]  G. S. Wilson,et al.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. , 1991, Analytical chemistry.

[6]  S. Dong,et al.  Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material. , 1998, Analytical chemistry.

[7]  I Klimant,et al.  Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background. , 2000, Biosensors & bioelectronics.

[8]  H. Fujiwara,et al.  A micro-planar amperometric glucose sensor unsusceptible to interference species , 1998 .

[9]  Alexander M. Yacynych,et al.  Use of polymer films in amperometric biosensors , 1995 .

[10]  P. Vadgama,et al.  The modification of enzyme electrode properties with non-conducting electropolymerised films , 1995 .

[11]  J Wang,et al.  Electroanalysis and biosensors. , 1993, Analytical chemistry.

[12]  Baohong Liu,et al.  Al2O3 sol–gel derived amperometric biosensor for glucose , 1999 .

[13]  J. A. Hubbell,et al.  Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode. , 1994, Analytical chemistry.

[14]  S. Cosnier Electropolymerization of amphiphilic monomers for designing amperometric biosensors , 1997 .

[15]  P. Vadgama,et al.  Modification of electrode surfaces with oxidised phenols to confer selectivity to amperometric biosensors for glucose determination , 1993 .

[16]  Ovadia Lev,et al.  Organically modified sol-gel sensors , 1995 .

[17]  G. S. Wilson,et al.  Rapid Changes in Local Extracellular Rat Brain Glucose Observed with an In Vivo Glucose Sensor , 1997, Journal of neurochemistry.

[18]  L. Hench,et al.  The sol-gel process , 1990 .

[19]  C. Brinker,et al.  Sol-Gel Science: The Physics and Chemistry of Sol-Gel Processing , 1990 .

[20]  G. S. Wilson,et al.  Electrochemically mediated electrodeposition/electropolymerization to yield a glucose microbiosensor with improved characteristics. , 2002, Analytical chemistry.

[21]  G A Baker,et al.  Kinetics and thermodynamics of free flavins and the flavin-based redox active site within glucose oxidase dissolved in solution or sequestered within a sol-gel-derived glass. , 1999, Analytical chemistry.

[22]  Bruce Dunn,et al.  Sol-gel encapsulation methods for biosensors , 1994 .

[23]  W Kerner,et al.  Amperometric biosensor for in vivo glucose sensing based on glucose oxidase immobilized in a redox hydrogel. , 1994, Biosensors & bioelectronics.

[24]  G. S. Wilson,et al.  Biosensors : fundamentals and applications , 1987 .

[25]  G. S. Wilson,et al.  Elimination of the acetaminophen interference in an implantable glucose sensor. , 1994, Analytical chemistry.

[26]  David Avnir,et al.  Organic Chemistry within Ceramic Matrixes: Doped Sol-Gel Materials , 1995 .

[27]  M. Collinson,et al.  Sol-gels and electrochemistry: research at the intersection. , 2000, Analytical chemistry.

[28]  David Avnir,et al.  Enzymes and Other Proteins Entrapped in Sol-Gel Materials , 1994 .

[29]  Y. S. Lin,et al.  Sol–gel-derived mesoporous γ-alumina granules , 1999 .

[30]  S. Sampath,et al.  Sol−Gel Materials in Electrochemistry , 1997 .

[31]  Bengt Danielsson,et al.  Sol–gel based thermal biosensor for glucose , 2001 .

[32]  Gerald Urban,et al.  Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications , 1992 .

[33]  A. Larbot,et al.  Preparation of a γ-alumina nanofiltration membrane , 1994 .

[34]  Hsuan‐Jung Huang,et al.  An Amperometric Urea Biosensor Based on a Polyaniline−Perfluorosulfonated Ionomer Composite Electrode , 1998 .

[35]  Chris W. Brown,et al.  Sol-gel glass as a matrix for chemical and biochemical sensing , 1997 .

[36]  T. Yao,et al.  Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film. , 1998, Biosensors & bioelectronics.

[37]  D. J. Harrison,et al.  Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. , 1988, Analytical chemistry.

[38]  G. S. Wilson,et al.  In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor , 1993 .

[39]  Jonathan M. Cooper,et al.  A review of the immobilization of enzymes in electropolymerized films , 1993 .

[40]  P. Zambonin,et al.  Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer. , 1998, Biosensors & bioelectronics.

[41]  Bruce Dunn,et al.  Enzymatic activity of glucose oxidase encapsulated in transparent glass by the sol-gel method , 1992 .

[42]  M. Collinson Sol-Gel Strategies for the Preparation of Selective Materials for Chemical Analysis , 1999 .

[43]  G. S. Wilson,et al.  Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors. , 1996, Analytical chemistry.