Parametric Analysis of Design Parameter Effects on the Performance of a Solar Desiccant Evaporative Cooling System in Brisbane, Australia

Solar desiccant cooling is widely considered as an attractive replacement for conventional vapor compression air conditioning systems because of its environmental friendliness and energy efficiency advantages. The system performance of solar desiccant cooling strongly depends on the input parameters associated with the system components, such as the solar collector, storage tank and backup heater, etc. In order to understand the implications of different design parameters on the system performance, this study has conducted a parametric analysis on the solar collector area, storage tank volume, and backup heater capacity of a solid solar desiccant cooling system for an office building in Brisbane, Australia climate. In addition, a parametric analysis on the outdoor air humidity ratio control set-point which triggers the operation of the desiccant wheel has also been investigated. The simulation results have shown that either increasing the storage tank volume or increasing solar collector area would result in both increased solar fraction ( SF ) and system coefficient of performance ( COP ), while at the same time reduce the backup heater energy consumption. However, the storage tank volume is more sensitive to the system performance than the collector area. From the economic aspect, a storage capacity of 30 m 3 /576 m 2 has the lowest life cycle cost ( LCC ) of $405,954 for the solar subsystem. In addition, 100 kW backup heater capacity is preferable for the satisfaction of the design regeneration heating coil hot water inlet temperature set-point with relatively low backup heater energy consumption. Moreover, an outdoor air humidity ratio control set-point of 0.008 kgWater/kgDryAir is more reasonable, as it could both guarantee the indoor design conditions and achieve low backup heater energy consumption.

[1]  Lisa Guan,et al.  Techno-economic Analysis of a Solar Desiccant-Evaporative Cooling System with Different Collector Types for Australian Office Buildings , 2015 .

[2]  Yunlong Ma Investigation of advanced solar assisted cooling for Australian commercial buildings , 2016 .

[3]  Vassilis Belessiotis,et al.  Solid desiccant air-conditioning systems Design parameters , 2011 .

[4]  D. Daly,et al.  Implications of global warming for commercial building retrofitting in Australian cities , 2014 .

[5]  Alessio Sapienza,et al.  A dynamic multi-level model for adsorptive solar cooling , 2011 .

[6]  Yunlong Ma,et al.  Performance Analysis of Solar Desiccant-Evaporative Cooling for a Commercial Building under Different Australian Climates , 2015 .

[7]  Aileen Marie,et al.  AIR TIGHTNESS OF AUSTRALIAN OFFICES BUILDINGS: REALITY VERSUS TYPICAL ASSUMPTIONS USED IN ENERGY PERFORMANCE SIMULATION. , 2011 .

[8]  Carlo Roselli,et al.  Assessment of Energy, Environmental and Economic Performance of a Solar Desiccant Cooling System with Different Collector Types , 2014 .

[9]  Masoud Mohammadian,et al.  Optimization of solar collector surface in solar desiccant wheel cycle , 2012 .

[10]  Paul Kohlenbach,et al.  Indoor temperature variations resulting from solar desiccant cooling in a building without thermal backup , 2009 .

[11]  Mohammad Masud Kamal. Khan,et al.  Analysis of solar desiccant cooling system for an institutional building in subtropical Queensland, Australia , 2012 .

[12]  Paul Cooper,et al.  Understanding the risks and uncertainties introduced by common assumptions in energy simulations for Australian commercial buildings , 2014 .

[13]  Tianshu Ge,et al.  Performance comparison between a solar driven rotary desiccant cooling system and conventional vapor compression system (performance study of desiccant cooling) , 2010 .

[14]  Hans-Martin Henning,et al.  Solar assisted air conditioning of buildings – an overview , 2004 .

[15]  Carlo Roselli,et al.  Performance Assessment of a Solar-Assisted Desiccant-Based Air Handling Unit Considering Different Scenarios , 2016 .

[16]  Kamaruzzaman Sopian,et al.  Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia , 2014 .

[17]  Shafiqur Rehman,et al.  Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System , 2016 .

[18]  Yunfei Dai,et al.  Case study of a two-stage rotary desiccant cooling/heating system driven by evacuated glass tube solar air collectors , 2012 .

[19]  Mohammad Masud Kamal. Khan,et al.  Comparison study of solar cooling technologies for an institutional building in subtropical Queensland, Australia , 2013 .

[20]  Hans Martin Henning Solar Assisted Air-Conditioning in Buildings , 1993 .

[21]  D. A. Hindoliya,et al.  Performance of solid desiccant-based evaporative cooling system under the climatic zones of India , 2013 .

[22]  Mario Motta,et al.  Solar Cooling Handbook: A Guide to Solar Assisted Cooling and Dehumidification Processes , 2013 .

[23]  Shafiqur Rehman,et al.  Analysis of a Solar Cooling System for Climatic Conditions of Five Different Cities of Saudi Arabia , 2016 .

[24]  Carey J. Simonson,et al.  Thermo-economic performance of a solar membrane liquid desiccant air conditioning system , 2014 .

[25]  M. Goldsworthy,et al.  Optimisation of a desiccant cooling system design with indirect evaporative cooler , 2011 .