Precise Estimation of Postoperative Cup Alignment from Single Standard X-Ray Radiograph with Gonadal Shielding

This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.

[1]  B Jaramaz,et al.  Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment , 1998, Clinical orthopaedics and related research.

[2]  Branislav Jaramaz,et al.  2D/3D Registration for Measurement of Implant Alignment After Total Hip Replacement , 2006, MICCAI.

[3]  F. Veldpaus,et al.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. , 1988, Journal of biomechanics.

[4]  Guoyan Zheng,et al.  Point Similarity Measures Based on MRF Modeling of Difference Images for Spline-Based 2D-3D Rigid Registration of X-Ray Fluoroscopy to CT Images , 2006, WBIR.

[5]  R. Diercks,et al.  Digital radiographic preoperative planning and postoperative monitoring of total hip replacements , 2006 .

[6]  Takeo Kanade,et al.  Post-Operative Measurement of Acetabular Cup Position Using X-Ray/CT Registration , 2000, MICCAI.

[7]  Gerd Hirzinger,et al.  Registration of CAD-models to images by iterative inverse perspective matching , 1996, Proceedings of 13th International Conference on Pattern Recognition.

[8]  Guoyan Zheng,et al.  An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images , 2006, Int. J. Biomed. Imaging.

[9]  Guoyan Zheng,et al.  A hybrid CT-free navigation system for total hip arthroplasty. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[10]  Lars Perlick,et al.  Position of the acetabular cup -- accuracy of radiographic calculation compared to CT-based measurement. , 2006, European journal of radiology.

[11]  Craig J Della Valle,et al.  Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. , 2004, The Journal of arthroplasty.

[12]  R. Pradhan,et al.  Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. , 1999, The Journal of bone and joint surgery. British volume.