Variability of automated visual fields in clinically stable glaucoma patients.

The total variability of the visual field was measured in 20 patients with open-angle glaucoma who appeared to be clinically stable and well controlled on medical therapy. All patients had at least four visual fields performed on the Octopus 201 perimeter with at least 12 months follow-up since their first visual field. The four most recently performed visual fields were analyzed. Two different methods for calculating total variability were used. One was based on the variance of the threshold determinations and the other was based on the range. The average total variability per subject was 2.8 decibels (db) using the variance-based calculation and 5.1 db using the range-based calculation. Ninety-five percent of the test locations had a variability of less than 6 db by the variance-based calculation method and 13 db by the range-based calculation method. We discuss the possibility of using this type of data to develop criteria for detection of progressive visual field loss in glaucoma.

[1]  The perimeter as a monitor of glaucomatous changes. , 1978, The British journal of ophthalmology.

[2]  G. Lindgren,et al.  Normal variability of static perimetric threshold values across the central visual field. , 1987, Archives of ophthalmology.

[3]  H. D. Hoskins,et al.  Confidence intervals for change in automated visual fields. , 1988, The British journal of ophthalmology.

[4]  R. Fellman,et al.  Internal Inconsistencies vs Root Mean Square as Measures of Threshold Variability , 1985 .

[5]  J Katz,et al.  A longitudinal study of the age-adjusted variability of automated visual fields. , 1987, Archives of ophthalmology.

[6]  J Flammer,et al.  Differential light threshold. Short- and long-term fluctuation in patients with glaucoma, normal controls, and patients with suspected glaucoma. , 1984, Archives of ophthalmology.

[7]  E. Werner,et al.  Variability of static visual threshold responses in patients with elevated IOPs. , 1982, Archives of ophthalmology.

[8]  J L Keltner,et al.  Variability of quantitative automated perimetry in normal observers. , 1986, Ophthalmology.

[9]  B. Gloor,et al.  Long-term fluctuations versus actual field loss in glaucoma patients. , 1985, Developments in ophthalmology.

[10]  S. Drance,et al.  The Estimation and Testing of the Components of Long-Term Fluctuation of the Differential Light Threshold , 1983 .

[11]  C. Krakau,et al.  REGRESSION ANALYSIS OF THE CENTRAL VISUAL FIELD IN CHRONIC GLAUCOMA CASES , 1982, Acta ophthalmologica.

[12]  H Bebie,et al.  STATIC PERIMETRY: ACCURACY AND FLUCTUATIONS , 1976, Acta ophthalmologica.

[13]  F. Fankhauser,et al.  Statistical Program for the Analysis of Perimetric Data , 1981 .

[14]  Robert Parsons Statistical Analysis: A Decision-Making Approach , 1974 .

[15]  S. Drance,et al.  Covariates of the long-term fluctuation of the differential light threshold. , 1984, Archives of ophthalmology.

[16]  W. Argus,et al.  Fluctuations on the Humphrey and Octopus perimeters. , 1987, Investigative ophthalmology & visual science.

[17]  E. Werner,et al.  Effect of patient experience on the results of automated perimetry in clinically stable glaucoma patients. , 1988, Ophthalmology.

[18]  R. P. Mills,et al.  A comparison of experienced clinical observers and statistical tests in detection of progressive visual field loss in glaucoma using automated perimetry. , 1988, Archives of ophthalmology.

[19]  Erik L. Greve,et al.  RESULTS OF A FLUCTUATION ANALYSIS AND DEFECT VOLUME PROGRAM FOR AUTOMATED STATIC THRESHOLD PERIMETRY WITH THE SCOPERIMETER , 1985 .

[20]  S M Drance,et al.  Early visual field disturbances in glaucoma. , 1977, Archives of ophthalmology.

[21]  F. Fankhauser,et al.  Differential light threshold in automated static perimetry. Factors influencing short-term fluctuation. , 1984, Archives of ophthalmology.

[22]  Anders Heijl,et al.  A Simple Routine for Demonstrating Increased Threshold Scatter by Comparing Stored Computer Fields , 1985 .

[23]  F. Fankhauser,et al.  Threshold Fluctuations, Interpolations and Spatial Resolution in Perimetry , 1979 .

[24]  B. Joondeph,et al.  Variation in visual field measurements with an automated perimeter. , 1984, American journal of ophthalmology.