Transcutaneous bilirubin measurement: comparison of Respironics BiliCheck and JM-103 in a normal newborn population.

OBJECTIVES To compare the accuracy of BiliCheck™ (Respironics, Marietta, GA) and Konica-Minolta Air Shield JM-103 (Drager Medical Inc, Telford, PA) to evaluate total serum bilirubin (TSB). METHODS Prospective blinded study comparing two diagnostic devices in 630 neonates requiring TSB measurement. RESULTS Linear regression analysis showed a good correlation between BiliCheck™ and TSB (r=0.8212) as well as between JM-103 and TSB (r=0.8686). BiliCheck shows a tendency to underestimate TSB. The mean difference in TSB-TcB was -1.4 mg/dL for BC (-4.7/+1.8 mg/dL) and 0.3 mg/dL for JM-103 (-2.6/+3.2mg/dL). ROC analysis for TSB≥ 12 mg/dL showed area under the curve for BiliCheck™ significantly lower than those for JM-103 (p<0.0001). JM-103 resulted less time expensive than BiliCheck. CONCLUSIONS In spite of similar diagnostic accuracy JM-103 could be preferred for some practical advantages, but its suitability in performing universal screening for severe hyperbilirubinemia deserves further investigations.

[1]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[2]  R. Sege,et al.  An evidence-based review of important issues concerning neonatal hyperbilirubinemia. , 2004, Pediatrics.

[3]  V. Moyer,et al.  Accuracy of clinical judgment in neonatal jaundice. , 2000, Archives of pediatrics & adolescent medicine.

[4]  Transcutaneous bilirubinometry and diagnostic tests: "the right job for the tool". , 2002, Pediatrics.

[5]  V. Grey,et al.  Clinical implication of the difference between transcutaneous bilirubinometry and total serum bilirubin for the classification of newborns at risk of hyperbilirubinemia. , 2009, Clinical biochemistry.

[6]  Subcommittee on Hyperbilirubinemia Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. , 2004, Pediatrics.

[7]  Deborah Talbot,et al.  Evaluation of a new transcutaneous bilirubinometer. , 2004, Pediatrics.

[8]  G. Gourley,et al.  Direct spectrophotometric method for measurement of bilirubin in newborns: comparison with HPLC and an automated diazo method. , 2002, Clinical chemistry.

[9]  V. Bhutani,et al.  Measuring bilirubin through the skin? , 2003, Pediatrics.

[10]  J. Simonoff Smoothing Methods in Statistics , 1998 .

[11]  C. Romagnoli,et al.  Attempt to improve transcutaneous bilirubinometry: a double-blind study of Medick BiliMed versus Respironics BiliCheck , 2007, Archives of Disease in Childhood Fetal and Neonatal Edition.

[12]  C. Romagnoli,et al.  Using BiliCheck for preterm neonates in a sub-intensive unit: diagnostic usefulness and suitability. , 2007, Early human development.

[13]  Matthias Nauck,et al.  Bilirubin Measurement for Neonates: Comparison of 9 Frequently Used Methods , 2006, Pediatrics.

[14]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[15]  William D. Dupont,et al.  PS power and sample size program available for free on the internet , 1997 .