[Quantitative Evaluation of Metal Artifacts on CT Images on the Basis of Statistics of Extremes].

It is well-known that metal artifacts have a harmful effect on the image quality of computed tomography (CT) images. However, the physical property remains still unknown. In this study, we investigated the relationship between metal artifacts and tube currents using statistics of extremes. A commercially available phantom for measuring CT dose index 160 mm in diameter was prepared and a brass rod 13 mm in diameter was placed at the centerline of the phantom. This phantom was used as a target object to evaluate metal artifacts and was scanned using an area detector CT scanner with various tube currents under a constant tube voltage of 120 kV. Sixty parallel line segments with a length of 100 pixels were placed to cross metal artifacts on CT images and the largest difference between two adjacent CT values in each of 60 CT value profiles of these line segments was employed as a feature variable for measuring metal artifacts; these feature variables were analyzed on the basis of extreme value theory. The CT value variation induced by metal artifacts was statistically characterized by Gumbel distribution, which was one of the extreme value distributions; namely, metal artifacts have the same statistical characteristic as streak artifacts. Therefore, Gumbel evaluation method makes it possible to analyze not only streak artifacts but also metal artifacts. Furthermore, the location parameter in Gumbel distribution was shown to be in inverse proportion to the square root of a tube current. This result suggested that metal artifacts have the same dose dependence as image noises.

[1]  Lajos Pusztai,et al.  A Randomized, Controlled Trial of Cavity Shave Margins in Breast Cancer. , 2015, The New England journal of medicine.

[2]  Joon Koo Han,et al.  Usefulness of a metal artifact reduction algorithm for orthopedic implants in abdominal CT: phantom and clinical study results. , 2015, AJR. American journal of roentgenology.

[3]  A. Blum,et al.  Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures , 2014, Skeletal Radiology.

[4]  Yang Wang,et al.  Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis. , 2013, European journal of radiology.

[5]  Mitsuru Ikeda,et al.  Method of measuring contrast-to-noise ratio (CNR) in nonuniform image area in digital radiography , 2013 .

[6]  M Yamauchi,et al.  Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings. , 2012, The British journal of radiology.

[7]  Mitsuru Ikeda,et al.  Statistical characteristics of streak artifacts on CT images: relationship between streak artifacts and mA s values. , 2009, Medical physics.

[8]  T. Niimi,et al.  Analysis of streak artefacts on CT images using statistics of extremes. , 2007, The British journal of radiology.

[9]  J. Willmann,et al.  Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility. , 2004, Radiology.