Application of the fast-evaporation sample preparation method for improving quantification of angiotensin II by matrix-assisted laser desorption/ionization.

The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects. Improvement in sample homogeneity using the fast-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method. The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675 amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.

[1]  A. Proctor,et al.  Improvement of signal reproducibility and matrix/comatrix effects in MALDI analysis , 1995 .

[2]  M. Mann,et al.  Improved mass accuracy in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of peptides , 1994, Journal of the American Society for Mass Spectrometry.

[3]  Peter Roepstorff,et al.  Improved resolution and very high sensitivity in MALDI TOF of matrix surfaces made by fast evaporation , 1994 .

[4]  D. Muddiman,et al.  Quantitative measurement of cyclosporin A in blood by time-of-flight mass spectrometry. , 1994, Analytical chemistry.

[5]  L. Sturiale,et al.  Quantitative determination of β(1–2) cyclic glucans by matrix-assisted laser desorption mass spectrometry , 1994 .

[6]  T. Hutchens,et al.  Quantitative Determination of Proteins by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry , 1994 .

[7]  W. Herzer,et al.  3-isobutyl-1-methylxanthine decreases renal cortical interstitial levels of adenosine and inosine. , 1994, Life sciences.

[8]  M. Duncan,et al.  Quantitative analysis of low molecular weight compounds of biological interest by matrix-assisted laser desorption ionization. , 1993, Rapid communications in mass spectrometry : RCM.

[9]  Kermit K. Murray,et al.  Reproducibility and quantitation of matrix-assisted laser desorption ionization mass spectrometry: effects of nitrocellulose on peptide ion yields. , 1993, Biological mass spectrometry.

[10]  A. Proctor,et al.  Quantitative Analysis of Peptides by Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry , 1993 .

[11]  Chung-Hsuan Chen,et al.  Quantitative analysis of biopolymers by matrix-assisted laser desorption , 1993 .

[12]  J. Miller,et al.  Statistics for Analytical Chemistry , 1993 .

[13]  D. Harvey Quantitative aspects of the matrix-assisted laser desorption mass spectrometry of complex oligosaccharides. , 1993, Rapid communications in mass spectrometry : RCM.

[14]  J. Stults,et al.  Tryptic mapping of recombinant proteins by matrix-assisted laser desorption/ionization mass spectrometry. , 1993, Analytical chemistry.

[15]  M. Seikaly,et al.  Endogenous angiotensin concentrations in specific intrarenal fluid compartments of the rat. , 1990, The Journal of clinical investigation.

[16]  D. Burns,et al.  Statistics for analytical chemistry (2nd edn): By J. C. Miller and J. N. Miller. Pp. 227. Ellis Horwood, Chichester. 1988. Paperback £9.95 , 1988 .

[17]  Jack L. Koenig,et al.  A New Baseline Correction Algorithm Using Objective Criteria , 1987 .

[18]  Carl de Boor,et al.  A Practical Guide to Splines , 1978, Applied Mathematical Sciences.

[19]  C. Reinsch Smoothing by spline functions , 1967 .