Convenient, Rapid and Accurate Measurement of SVOC Emission Characteristics in Experimental Chambers

Chamber tests are usually used to determine the source characteristics of semi-volatile organic compounds (SVOCs) which are critical to quantify indoor exposure to SVOCs. In contrast to volatile organic compounds (VOCs), the sorption effect of SVOCs to chamber surfaces usually needs to be considered due to the much higher surface/air partition coefficients, resulting in a long time to reach steady state, frequently on the order of months, and complicating the mathematical analysis of the resulting data. A chamber test is also complicated if the material-phase concentration is not constant. This study shows how to design a chamber to overcome these limitations. A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surfaces, (2) neglecting the convective mass transfer resistance at sorption surfaces if the sorption effect cannot be neglected, and (3) regarding the material-phase concentration in the source as constant. Several practical and quantifiable ways to improve chamber design are proposed. The approach is illustrated by analyzing available data from three different chambers in terms of the accuracy with which the model parameters can be determined and the time needed to conduct the chamber test. The results should greatly facilitate the design of chambers to characterize SVOC emissions and the resulting exposure.

[1]  William W. Nazaroff,et al.  Semivolatile organic compounds in indoor environments , 2008 .

[2]  Ruthann A Rudel,et al.  Endocrine disrupting chemicals in indoor and outdoor air. , 2009, Atmospheric environment.

[3]  M. Diamond,et al.  Evidence for Organic Film on an Impervious Urban Surface: Characterization and Potential Teratogenic Effects , 2000 .

[4]  T. Salthammer,et al.  Phthalic esters in the indoor environment--test chamber studies on PVC-coated wallcoverings. , 2001, Indoor air.

[5]  C. Junge Basic considerations about trace constituents in the atmosphere as related to the fate of global pollutants. , 1977 .

[6]  Ashok J. Gadgil,et al.  Modeling Emissions of Volatile Organic Compounds from New Carpets , 1994 .

[7]  Robert C Hale,et al.  Potential role of fire retardant-treated polyurethane foam as a source of brominated diphenyl ethers to the US environment. , 2002, Chemosphere.

[8]  Yinping Zhang,et al.  Role of aerosols in enhancing SVOC flux between air and indoor surfaces and its influence on exposure , 2012 .

[9]  Elaine A Cohen Hubal,et al.  Predicting residential exposure to phthalate plasticizer emitted from vinyl flooring: a mechanistic analysis. , 2009, Environmental science & technology.

[10]  M. Wensing,et al.  Plastics additives in the indoor environment--flame retardants and plasticizers. , 2005, The Science of the total environment.

[11]  Charles J. Weschler,et al.  Changes in indoor pollutants since the 1950s , 2009 .

[12]  C. Bornehag,et al.  Phthalate exposure and asthma in children. , 2010, International journal of andrology.

[13]  Jinsoo Park,et al.  Measuring and predicting the emission rate of phthalate plasticizer from vinyl flooring in a specially-designed chamber. , 2012, Environmental science & technology.

[14]  W. Nazaroff,et al.  SVOC partitioning between the gas phase and settled dust indoors , 2010 .

[15]  Bin Zhao,et al.  The influence of aerosol dynamics on indoor exposure to airborne DEHP , 2010 .

[16]  H Rüden,et al.  Occurrence of phthalates and musk fragrances in indoor air and dust from apartments and kindergartens in Berlin (Germany). , 2004, Indoor air.

[17]  John C. Little,et al.  Rapid methods to estimate potential exposure to semivolatile organic compounds in the indoor environment. , 2012, Environmental science & technology.

[18]  Ying Xu,et al.  An improved mass transfer based model for analyzing VOC emissions from building materials , 2003 .

[19]  Ying Xu,et al.  Predicting emissions of SVOCs from polymeric materials and their interaction with airborne particles. , 2006, Environmental science & technology.

[20]  John C. Little,et al.  Predicting Residential Exposure to Phthalate Plasticizer Emitted from Vinyl Flooring: Sensitivity, Uncertainty, and Implications for Biomonitoring , 2009, Environmental health perspectives.

[21]  Bin Zhao,et al.  Indoor SVOC pollution in China: A review , 2010 .

[22]  John C. Little,et al.  Influence of air flow rate on emission of DEHP from vinyl flooring in the emission cell FLEC: Measurements and CFD simulation , 2010 .

[23]  R. Kruse,et al.  Decrease in Anogenital Distance among Male Infants with Prenatal Phthalate Exposure , 2005, Environmental health perspectives.

[24]  John D Spengler,et al.  Asthma, wheezing, and allergies in Russian schoolchildren in relation to new surface materials in the home. , 2004, American journal of public health.

[25]  Mutsuko Hirata-Koizumi,et al.  Potential adverse effects of phthalic acid esters on human health: a review of recent studies on reproduction. , 2008, Regulatory toxicology and pharmacology : RTP.