Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK.

OBJECTIVES To assess the bonding potential of a universal composite resin cement and an adhesive/composite system to differently pre-treated PEEK surfaces. METHODS One hundred and fifty PEEK disks were embedded in epoxy resin, polished (P4000 grit) and treated as follows (n=30/group): (A) no treatment, (B) acid etching with sulfuric acid (98%) for 1 min, (C) sandblasting for 10s with 50 microm alumina, (D) sandblasting for 10s with 110 microm alumina and (E) silica coating using the Rocatec system (3M ESPE). Polished and sandblasted (50 microm alumina) cp titanium (grade 4) served as a control. Acrylic hollow cylinders were either luted with a universal composite resin cement (RelyX Unicem) or an unfilled resin (Heliobond) and a hybrid composite (Tetric) to the specimens. Bond strength was measured in a shear test and failure modes were assessed. Statistic analysis was performed with one-way ANOVA followed by a post hoc Scheffé test and unpaired t-tests. RESULTS With the universal composite resin cement, no bond could be established on any PEEK surfaces, except specimens etched with sulfuric acid (19.0+/-3.4MPa). Shear bond strength to titanium was significantly lower (8.7+/-2.8MPa, p<0.05). Applying the adhesive/composite system, shear bond strength values on pre-treated PEEK ranged from 11.5+/-3.2MPa (silica coating) to 18.2+/-5.4MPa (acid etched) with no statistically significant differences (p>0.05). No bond was obtained on the polished surface. SIGNIFICANCE Bonding to PEEK is possible when using a bonding system. No adherence can be achieved with the tested universal composite resin cement except on an etched surface. The results strongly encourage further research in PEEK application in dentistry.

[1]  Zoran R. Vulicevic,et al.  Self-adhesive resin cements: a literature review. , 2008, The journal of adhesive dentistry.

[2]  S. Kurtz,et al.  PEEK biomaterials in trauma, orthopedic, and spinal implants. , 2007, Biomaterials.

[3]  Evan D Tetelman,et al.  A New Transitional Abutment for Immediate Aesthetics and Function , 2008, Implant dentistry.

[4]  T. Gerds,et al.  Influence of different adhesive resin cements on the fracture strength of aluminum oxide ceramic posterior crowns. , 2004, The Journal of prosthetic dentistry.

[5]  G. Rune,et al.  Chemical micropatterning of polymeric cell culture substrates using low-pressure hydrogen gas discharge plasmas , 1999, Journal of materials science. Materials in medicine.

[6]  O. Noiset,et al.  Adhesion and growth of CaCo2 cells on surface-modified PEEK substrata , 2000, Journal of biomaterials science. Polymer edition.

[7]  M. Kern,et al.  Retention forces and seating discrepancies of implant-retained castings after cementation. , 2006, The International journal of oral & maxillofacial implants.

[8]  John A Sorensen,et al.  In vitro shear bond strength of cementing agents to fixed prosthodontic restorative materials. , 2004, The Journal of prosthetic dentistry.

[9]  M. Behr,et al.  Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[10]  D. Feldman Engineering thermoplastics‐properties and applications, James M. Margolis, Ed., Marcel Dekker, New York, 1985, 393 pp. , 1986 .

[11]  C. Hämmerle,et al.  Shear bond strength of resin cements to human dentin. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[12]  H. Mark,et al.  Encyclopedia of polymer science and engineering , 1985 .