Motion artifact removal from muscle NIR Spectroscopy measurements

Near Infrared Spectroscopy (NIRS) is an optical method used for monitoring local tissue oxygenation and hemodynamics. This method is becoming increasingly popular in clinical and research applications. One important shortcoming of NIRS is an extreme sensitivity to motion artifacts. In this paper, we propose a new algorithm for removing movement artifacts from NIRS signals. We applied wavelet transform and then used the signal representation in the wavelet domain to isolate the artifacts and remove them using statistical testing. We tested this method on both simulated and experimental NIRS data acquired in a leg fracture operation and compared the results with those of median filtering, FIR filtering and wavelet SURE threshold estimation methods. The results show that the method significantly reduces the artifacts without distorting the signal in artifact free regions and outperforms other artifact removal methods.

[1]  Meltem Izzetoglu,et al.  Motion artifact cancellation in NIR spectroscopy using Wiener filtering , 2005, IEEE Transactions on Biomedical Engineering.

[2]  F. Mosteller,et al.  Understanding robust and exploratory data analysis , 1985 .

[3]  P. Arenth,et al.  Applications of Functional Near-Infrared Spectroscopy (fNIRS) to Neurorehabilitation of Cognitive Disabilities , 2007, The Clinical neuropsychologist.

[4]  I. Johnstone,et al.  Ideal spatial adaptation by wavelet shrinkage , 1994 .

[5]  Willy N. Colier,et al.  New and highly sensitive continuous-wave near-infrared spectrophotometer with multiple detectors , 1998, European Conference on Biomedical Optics.

[6]  Meltem Izzetoglu,et al.  Motion artifact removal in FNIR spectroscopy for real-world applications , 2004, SPIE Optics East.

[7]  Shirley Coyle,et al.  On the suitability of near-infrared (NIR) systems for next-generation brain-computer interfaces. , 2004, Physiological measurement.

[8]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[9]  Xiao-Ping Zhang,et al.  Adaptive denoising based on SURE risk , 1998, IEEE Signal Processing Letters.

[10]  Guy A. Dumont,et al.  Do radio frequencies of medical instruments common in the operating room interfere with near-infrared spectroscopy signals? , 2010, BiOS.

[11]  Truong Q. Nguyen,et al.  Wavelets and filter banks , 1996 .

[12]  F. Jöbsis Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. , 1977, Science.

[13]  T Binzoni,et al.  Oxidative metabolism in muscle. , 1997, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.