Determination of differential inductances of permanent magnet synchronous machines for sensorless control

This paper presents a novel approach for measuring the differential inductances in a permanent magnet synchronous machine (PMSM). The knowledge of their accurate values is a prerequisite for sensorless vector controlled systems with carrier signal injection. For the measurements a standard industrial power converter is used. Besides the determination of self-inductances in the rotor-fixed reference frame, the measurement of the cross-coupling differential inductances namely the cross saturation is a main part. A high frequency sine signal injection method is used for this purpose. The measurement is compared with the result of FEM calculations. In the second part the influence of the rotor position and the machine load in steady state on the high frequency current amplitude in the quadrature axis is analysed, while the signal is only injected in the direct axis. The results of these measurements are compared with saturation effects in the machine.

[1]  Ralph Kennel,et al.  Sensorless speed and position control of synchronous machines using alternating carrier injection , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..

[2]  Ingo Hahn Differential magnetic anisotropy - prerequisite for rotor position detection of PM-synchronous machines with signal injection methods , 2010, 2010 First Symposium on Sensorless Control for Electrical Drives.

[3]  Bernhard Piepenbreier,et al.  Identification of ohmic stator resistance based on low frequency current signal injection in permanent magnet synchronous machines , 2010, Proceedings of 14th International Power Electronics and Motion Control Conference EPE-PEMC 2010.

[4]  R.D. Lorenz,et al.  Implementation issues for fast initial position and magnet polarity identification of PM synchronous machines with near zero saliency , 2005, 2005 European Conference on Power Electronics and Applications.

[5]  M. Trlep,et al.  Evaluation of saturation and cross-magnetization effects in interior permanent magnet synchronous motor , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[6]  Peter Vas,et al.  Sensorless vector and direct torque control , 1998 .