Adaptive Zone-1 Setting Following Structural and Operational Changes in Power System

Change in the network structure or operating condition in a power system affects the impedance as calculated by the distance relay during fault. Such changes may lead to malfunction of the distance relay at times. In this paper, an adaptive distance relay setting method using local data is proposed to prevent zone-1 malfunction following structural and operational changes. The performance of the proposed adaptive setting method is tested on a 39-bus New England system and a generic 12-bus power system using PSCAD/EMTDC simulation data, and a comparative assessment is also provided.

[1]  S. C. Srivastava,et al.  A Classification Approach Using Support Vector Machines to Prevent Distance Relay Maloperation Under Power Swing and Voltage Instability , 2012, IEEE Transactions on Power Delivery.

[2]  A.S. Bretas,et al.  Ground Distance Relaying With Fault-Resistance Compensation for Unbalanced Systems , 2008, IEEE Transactions on Power Delivery.

[3]  Sinisa Zubic,et al.  Impedance surfing method for CVT transient mitigation , 2016, 2016 10th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG).

[4]  B. Kaszteny,et al.  Distance relays and capacitive voltage transformers balancing speed and transient overreach , 2000 .

[5]  U.D. Annakkage,et al.  A platform for validation of FACTS models , 2006, IEEE Transactions on Power Delivery.

[6]  Mladen Kezunovic,et al.  Reliable Implementation of Robust Adaptive Topology Control , 2014, 2014 47th Hawaii International Conference on System Sciences.

[7]  Michael J. Thompson,et al.  Transmission line setting calculations - beyond the cookbook , 2015, 2015 68th Annual Conference for Protective Relay Engineers.

[8]  S. A. Soman Analysis of angle stability problems: a transmission protection systems perspective , 2004 .

[9]  Gregory A. Franklin,et al.  Determining distance relay Zone-1 reach settings to prevent CCVT transient overreach , 2011, 2011 Proceedings of IEEE Southeastcon.

[10]  Zhiqian Bo,et al.  Efforts on Improving the Performance of Superimposed-Based Distance Protection , 2012, IEEE Transactions on Power Delivery.

[11]  Zhang Zhe,et al.  Research of one new adaptive mho relay , 2002, Proceedings. International Conference on Power System Technology.

[12]  M. Kezunovic,et al.  Automated Review of Distance Relay Settings Adequacy After the Network Topology Changes , 2016, IEEE Transactions on Power Delivery.

[13]  Michael J. Thompson,et al.  A tutorial on calculating source impedance ratios for determining line length , 2015, 2015 68th Annual Conference for Protective Relay Engineers.

[14]  B. R. Bhalja,et al.  A New Digital Distance Relaying Scheme for Compensation of High-Resistance Faults on Transmission Line , 2012, IEEE Transactions on Power Delivery.

[15]  S.F. Huang,et al.  Adaptive Impedance Relay With Composite Polarizing Voltage Against Fault Resistance , 2008, IEEE Transactions on Power Delivery.

[16]  Mohammad Shahidehpour,et al.  Major Grid Blackouts: Analysis, Classification, and Prevention , 2013 .

[17]  Tapan Kumar Saha,et al.  Power system blackouts - literature review , 2009, 2009 International Conference on Industrial and Information Systems (ICIIS).

[18]  P. Moore,et al.  An investigation into the use of adaptive setting techniques for improved distance back-up protection , 1996 .

[19]  J Upendar,et al.  Comprehensive Adaptive Distance Relaying Scheme for Parallel Transmission Lines , 2011, IEEE Transactions on Power Delivery.

[20]  Bi Tianshu,et al.  Ground distance relaying algorithm for high resistance fault , 2010 .

[21]  A. K. David,et al.  Adaptive relay setting for stand-alone digital distance protection , 1994 .

[22]  K. Zimmerman,et al.  CVT transients revisited — Distance, directional overcurrent, and communications-assisted tripping concerns , 2012, 2012 65th Annual Conference for Protective Relay Engineers.

[23]  Pratim Kundu,et al.  Enhanced Protection Security Using the System Integrity Protection Scheme (SIPS) , 2016, IEEE Transactions on Power Delivery.

[24]  A.G. Phadke,et al.  Blackouts and relaying considerations - Relaying philosophies and the future of relay systems , 2006, IEEE Power and Energy Magazine.

[25]  Adam Dysko,et al.  Reachability Analysis for the Verification of Adaptive Protection Setting Selection Logic , 2014, IEEE Transactions on Power Delivery.

[26]  G. Joos,et al.  Adaptive Distance Relay Setting for Lines Connecting Wind Farms , 2007, IEEE Transactions on Energy Conversion.

[27]  E. Handschin,et al.  Algorithmic-knowledge-based adaptive coordination in transmission protection , 2002 .

[28]  L. van der Sluis,et al.  Adaptive distance protection of a double-circuit line using artificial neural nets , 1994 .

[29]  Jing Ma,et al.  An Adaptive Distance Protection Scheme Based on the Voltage Drop Equation , 2015, IEEE Transactions on Power Delivery.

[30]  Bogdan Kasztenny,et al.  Phase Selection for Single-Pole Tripping: Weak Infeed Conditions and Cross-Country Faults , 2002 .

[31]  Andrzej Adamczyk,et al.  Generic 12-bus test system for wind power integration studies , 2013, 2013 15th European Conference on Power Electronics and Applications (EPE).

[32]  Ramakrishna Gokaraju,et al.  A new method for blocking third zone distance relays during stable power swings , 2017 .

[33]  Loi Lei Lai,et al.  Stand alone intelligent digital distance relay , 2000 .